Page 28
BB4500-BB5000 Operating Manual
2.6.1
Electrical specifications
CLIMAX electrical equipment is suitable for use in the physical environment and
operating conditions specified below. When the physical environment or the oper-
ating conditions are outside those specified, consult CLIMAX before putting the
electrical equipment into service.
T
ABLE
2-20. E
LECTRICAL
SPECIFICATIONS
Mains voltage (AC):
±10% of nominal
Mains frequency (AC):
±1% of nominal
Mains harmonics:
10% of RMS volts
2nd through 30th harmonic
Voltage imbalance (3-phase supplies):
2% maximum
Voltage impulses:
200% of nominal
1.5 milliseconds (ms) maximum duration
Voltage interruption:
3 ms maximum with 1 second between
Voltage dip (brownout):
20% of peak volts for 1 second maximum
Voltage supplied from batteries:
±10% of nominal
Voltage interruption (DC):
5 ms maximum
Ambient temperature (operating):
41–104°F (5–40°C)
Ambient temperature (transport and
storage):
-13–131°F (-25–55°C)
Relative humidity:
20–95% non-condensing
Altitude:
6,600 ft (2,000 m)
Contaminants:
IP54 environment except for some motors
and slip ring assemblies that are IP 20
Available fault current:
Not greater than that listed on the controls
nameplate
Vibration
Pushbuttons:
5g at 5–300 Hz
Relays, contactors, and breakers:
2g at 5–300 Hz
Touchscreen HMI:
1g at 9–150 Hz
Servo amplifiers and PLC:
1g at 9–150 Hz
Physical shock (impact)
Pushbuttons:
30g for 18ms
Relays, contactors, and breakers:
6g for 11ms
Touchscreen HMI:
15g three times in X, Y, and Z
Servo amplifiers and PLC:
1g three times in X, Y, and Z
Summary of Contents for BB4500
Page 2: ......
Page 4: ...Page B BB4500 BB5000 Operating Manual CLIMAX GLOBAL LOCATIONS...
Page 5: ...P N 92974 Rev 1 Page C CE DOCUMENTATION...
Page 10: ...Page iv BB4500 BB5000 Operating Manual This page intentionally left blank...
Page 14: ...Page viii BB4500 BB5000 Operating Manual This page intentionally left blank...
Page 25: ...P N 92974 Rev 1 Page 9 FIGURE 1 2 RDU LABEL LOCATIONS...
Page 26: ...Page 10 BB4500 BB5000 Operating Manual This page intentionally left blank...
Page 46: ...Page 30 BB4500 BB5000 Operating Manual This page intentionally left blank...
Page 82: ...Page 66 BB4500 BB5000 Operating Manual FIGURE A 1 AXIAL FEED UNIT ASSEMBLY P N 43378 27 6 6 6...
Page 95: ...P N 92974 Rev 1 Page 79 FIGURE A 14 EIBENSTOCK MOTOR ASSEMBLY GEN 2 ONLY...
Page 114: ...Page 98 BB4500 BB5000 Operating Manual FIGURE B 15 SERVO DRIVE 460 CE ASSEMBLY P N 52876...
Page 120: ...Page 104 BB4500 BB5000 Operating Manual FIGURE B 21 SERVO DRIVE 230V CE ASSEMBLY P N 54321...
Page 127: ...P N 92974 Rev 1 Page 111 FIGURE B 28 EIBENSTOCK MOTOR ASSEMBLY GEN 2 ONLY...
Page 129: ...P N 92974 Rev 1 Page 113 FIGURE B 30 LEADSCREW ASSEMBLY P N 28654...
Page 134: ...Page 118 BB4500 BB5000 Operating Manual This page intentionally left blank...
Page 155: ...P N 92974 Rev 1 Page 139 FIGURE C 20 BB5000 SERVO PENDANT ASSEMBLY P N B00024...
Page 156: ...Page 140 BB4500 BB5000 Operating Manual This page intentionally left blank...
Page 158: ...Page 142 BB4500 BB5000 Operating Manual This page intentionally left blank...
Page 159: ...P N 92974 Rev 1 Page 143 APPENDIX E SDS Contact CLIMAX for the current Safety Data Sheets...
Page 160: ...Page 144 BB4500 BB5000 Operating Manual This page intentionally left blank...
Page 161: ......
Page 162: ......