Temperature Report: [COMMAND_CLASS_SENSOR_MULTILEVEL] [SENSOR_MULTILEVEL_REPORT] 

  The Smoke Detector can report temperature signal to the Control Panel every 30 to 33 minutes with Smoke Detector normal 

operating or when temperature changes by +/- 2

°

C. 

  Temperature: 01 22 

00 FA 

Sensor Type : 0x01 
Size : 2 
Scale : 0 
Precision : 1 

  If temperature signal 01 22 00 FA is transmitted, 

00 FA 

can be viewed as 

0x00FA

 in Hexadecimal number. You can convert 

hexadecimal to decimal and divide by 10 to check the temperature data (in Celsius). 

0x00FA=250=25.0

 

Summary of Contents for SD-29 Series

Page 1: ... up to determine a standard condition for the environment It can also be manually instructed to calibrate for air content It is also pre programmed to automatically calibrate once a month The Smoke Detector includes the following models Model Name Smoke Detection Temperature Sensor PIR Sensor Emergency Light SD 29 O SD 29 T O O SD 29 M O O SD 29 TM O O O SD 29 TME O O O O P Pa ar rt ts s I Id de e...

Page 2: ...e Control Panel in every 30 to 33 minutes with Smoke Detector normal operating or when temperature changes by 2 C Smoke Detection Once the concentration of the smoke exceeds the set threshold value the Smoke Detector lights up its Red LED to indicate it is sending the Smoke Alarm signal to the Z Wave Gateway Control Panel After the transmission is completed the Smoke Detector then activates its bu...

Page 3: ... In nc cl lu us si io on n The Smoke Detector can be included and operated in any Z Wave network with other Z Wave certified devices from other manufactures and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network Insert three 3V CR123 Lithium batteries into the battery compartment Orient the batte...

Page 4: ... Do not locate the detector in the following locations The Kitchen Smoke from cooking might cause an unwanted alarm Near a ventilating fan florescent lamp or air conditioning equipment air drafts from them may affect the sensitivity of the detector Near ceiling beams or over a cabinet stagnant air in these areas may affect the sensitivity of the detector In the peak of an A frame type of ceiling I...

Page 5: ...3 meters Mounting above 3 meters can affect detection performace SD 29 M SD 29 TM SD 29 TME only The Smoke Detector can support detection coverage within a radius of 4 meters Please refer to below figures for the installation details When mounted on the ceiling the PIR has better detection performance against horizontal movement ...

Page 6: ...Smoke Detector is restored it will send Basic Set 0x00 in Group 2 C Co om mm ma an nd d C Cl la as ss s D Da at ta a F Fo or rm ma at t Battery COMMAND_CLASS_BATTERY BATTERY_REPORT 0x64 100 Battery Full 0x4B 75 Battery 0x32 50 Battery 0x19 25 Battery 0xFF Battery Dead Cut Off Smoke Detection Triggered Smoke Detection Restored COMMAND_CLASS_NOTIFICATION NOTIFICATION_REPORT Smoke Alarm Triggered 00 ...

Page 7: ...3 minutes with Smoke Detector normal operating or when temperature changes by 2 C Temperature 01 22 00 FA Sensor Type 0x01 Size 2 Scale 0 Precision 1 If temperature signal 01 22 00 FA is transmitted 00 FA can be viewed as 0x00FA in Hexadecimal number You can convert hexadecimal to decimal and divide by 10 to check the temperature data in Celsius 0x00FA 250 25 0 ...

Reviews: