SD-29 series is a mini-sized wireless smoke detector with built-in PIR motion sensor, temperature sensor and emergency light (optional).
Designed to protect your family against potential fire hazards, the Smoke detector is also capable of detecting movements and reporting
temperature to users. The Z-Wave
Smoke Detector
allows access to the “S2 Unauthenticated” class.
The SD-29 is a wirelessly operated photo-electronic Smoke Detector designed to operate with any Z-Wave enabled controller devices; it also
features smoke detecting, temperature sensing and IR detection. The Smoke Detector
’s alarm situations, battery condition, operating conditions,
supervisory data and general fault information are sent to the Z-Wave Gateway/Control Panel wirelessly. The device is also serially connected
with other sensors in the Z-Wave gateway to serve as an extra siren.
The Smoke Detector is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Z-Wave is a wireless
communication protocol that uses a low-power RF radio. By taking advantage of the Z-Wave mesh network, commands can be transmitted to
their destination via intermediary “listening” Z-Wave products.
The Smoke Detector calibrates for the air contents after warming up to determine a standard condition for the environment. It can also be
manually instructed to calibrate for air content. It is also pre-programmed to automatically calibrate once a month.
The Smoke Detector includes the following models:
Model Name
Smoke Detection
Temperature Sensor
PIR Sensor
Emergency Light
SD-29
O
SD-29-T
O
O
SD-29-M
O
O
SD-29-TM
O
O
O
SD-29-TME
O
O
O
O
P
P
a
a
r
r
t
t
s
s
I
I
d
d
e
e
n
n
t
t
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
1. LED Indicator /Function Button / Emergency Light
Red LED
Turns ON briefly: Transmitting signal.
Quick flash: Alarming.
Flashes every 1 second: Smoke Detector under Sleep Mode
Flashes every 2 seconds: Smoke Detector under warmup and calibration process.
Flashes every 4 seconds: battery exhausted.
Orange LED
Flash every second: Device power on/Calibration failed.
Flashes every 5 seconds: Detecting smoke failed or device malfunctioning.
Flashes every 4 seconds: battery exhausted.
Flashes every 45 seconds: Low battery condition
Function Button
Press the button once to send test signal.
Press the button once during alarm to silence the alarm.
Press the button twice to discharge before inserting new batteries.
Press the button 3 times within 1.5 seconds to send a learn code.
Press and hold the button for 10 seconds to enter calibration process.
Press and hold the button for 20 seconds to perform factory reset.
White LED (Emergency Light)
The emergency light will begin to flash slowly to alert uses that the system is alarming.
(SD-29-TME only)
2. IR Lens
3. Buzzer
4. Battery Compartment Fixing Screw