SD-29  series  is  a  mini-sized  wireless  smoke  detector  with  built-in  PIR  motion  sensor,  temperature  sensor  and  emergency  light  (optional). 
Designed  to  protect  your  family  against  potential  fire  hazards,  the  Smoke  detector  is  also  capable  of  detecting  movements  and  reporting 
temperature to users. The Z-Wave

 Smoke Detector 

allows access to the “S2 Unauthenticated” class. 

The SD-29  is  a  wirelessly  operated  photo-electronic Smoke  Detector  designed to  operate  with  any  Z-Wave  enabled  controller  devices;  it  also 
features smoke detecting, temperature sensing and IR detection. The Smoke Detector

’s alarm situations, battery condition, operating conditions, 

supervisory data and general fault information are sent to the Z-Wave Gateway/Control Panel wirelessly. The device is also serially connected 
with other sensors in the Z-Wave gateway to serve as an extra siren. 

 

The  Smoke  Detector  is  a  Z-Wave  enabled  device  and  is  fully  compatible  with  any  Z-Wave  enabled  network.  Z-Wave  is  a  wireless 
communication protocol that uses a low-power RF radio. By taking advantage of the Z-Wave mesh network, commands can be transmitted to 
their destination via intermediary “listening” Z-Wave products. 

The  Smoke  Detector  calibrates  for  the  air  contents  after  warming  up  to  determine  a  standard  condition  for  the  environment.  It  can  also  be 
manually instructed to calibrate for air content. It is also pre-programmed to automatically calibrate once a month. 

The Smoke Detector includes the following models: 

Model Name 

Smoke Detection 

Temperature Sensor 

PIR Sensor 

Emergency Light 

SD-29 

O

 

 

 

 

SD-29-T 

O

 

 

 

SD-29-M 

O

 

 

 

SD-29-TM 

O

 

O

 

O

 

 

SD-29-TME 

O

 

O

 

O

 

O

 

 

 

P

P

a

a

r

r

t

t

s

s

 

 

I

I

d

d

e

e

n

n

t

t

i

i

f

f

i

i

c

c

a

a

t

t

i

i

o

o

n

n

 

 

 

 

 

 

1.  LED Indicator /Function Button / Emergency Light 

Red LED 

  Turns ON briefly: Transmitting signal. 

  Quick flash: Alarming. 

  Flashes every 1 second: Smoke Detector under Sleep Mode 

  Flashes every 2 seconds: Smoke Detector under warmup and calibration process.   

  Flashes every 4 seconds: battery exhausted. 

Orange LED 

  Flash every second: Device power on/Calibration failed. 

  Flashes every 5 seconds: Detecting smoke failed or device malfunctioning. 

  Flashes every 4 seconds: battery exhausted. 

  Flashes every 45 seconds: Low battery condition 

Function Button 

  Press the button once to send test signal.   

  Press the button once during alarm to silence the alarm. 

  Press the button twice to discharge before inserting new batteries. 

  Press the button 3 times within 1.5 seconds to send a learn code. 

  Press and hold the button for 10 seconds to enter calibration process. 

  Press and hold the button for 20 seconds to perform factory reset. 

White LED (Emergency Light)

 

  The emergency light will begin to flash slowly to alert uses that the system is alarming. 

(SD-29-TME only)

 

2.  IR Lens 

3.  Buzzer 

4.  Battery Compartment Fixing Screw 

Summary of Contents for SD-29 Series

Page 1: ... up to determine a standard condition for the environment It can also be manually instructed to calibrate for air content It is also pre programmed to automatically calibrate once a month The Smoke Detector includes the following models Model Name Smoke Detection Temperature Sensor PIR Sensor Emergency Light SD 29 O SD 29 T O O SD 29 M O O SD 29 TM O O O SD 29 TME O O O O P Pa ar rt ts s I Id de e...

Page 2: ...e Control Panel in every 30 to 33 minutes with Smoke Detector normal operating or when temperature changes by 2 C Smoke Detection Once the concentration of the smoke exceeds the set threshold value the Smoke Detector lights up its Red LED to indicate it is sending the Smoke Alarm signal to the Z Wave Gateway Control Panel After the transmission is completed the Smoke Detector then activates its bu...

Page 3: ... In nc cl lu us si io on n The Smoke Detector can be included and operated in any Z Wave network with other Z Wave certified devices from other manufactures and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network Insert three 3V CR123 Lithium batteries into the battery compartment Orient the batte...

Page 4: ... Do not locate the detector in the following locations The Kitchen Smoke from cooking might cause an unwanted alarm Near a ventilating fan florescent lamp or air conditioning equipment air drafts from them may affect the sensitivity of the detector Near ceiling beams or over a cabinet stagnant air in these areas may affect the sensitivity of the detector In the peak of an A frame type of ceiling I...

Page 5: ...3 meters Mounting above 3 meters can affect detection performace SD 29 M SD 29 TM SD 29 TME only The Smoke Detector can support detection coverage within a radius of 4 meters Please refer to below figures for the installation details When mounted on the ceiling the PIR has better detection performance against horizontal movement ...

Page 6: ...Smoke Detector is restored it will send Basic Set 0x00 in Group 2 C Co om mm ma an nd d C Cl la as ss s D Da at ta a F Fo or rm ma at t Battery COMMAND_CLASS_BATTERY BATTERY_REPORT 0x64 100 Battery Full 0x4B 75 Battery 0x32 50 Battery 0x19 25 Battery 0xFF Battery Dead Cut Off Smoke Detection Triggered Smoke Detection Restored COMMAND_CLASS_NOTIFICATION NOTIFICATION_REPORT Smoke Alarm Triggered 00 ...

Page 7: ...3 minutes with Smoke Detector normal operating or when temperature changes by 2 C Temperature 01 22 00 FA Sensor Type 0x01 Size 2 Scale 0 Precision 1 If temperature signal 01 22 00 FA is transmitted 00 FA can be viewed as 0x00FA in Hexadecimal number You can convert hexadecimal to decimal and divide by 10 to check the temperature data in Celsius 0x00FA 250 25 0 ...

Reviews: