background image

 

2. Break through the knockouts on the base. 
3. Use the holes as a template to drill two holes and insert the wall plugs. 
4. Screw the base into the wall plugs. 
5. Replace the top cover over the base by hooking the base onto the fixing hook and pushing the cover towards the 

base. 

6. Secure and screw the top cover back on to its base using a Philips screwdriver. 

 

Z-Wave Information 

Device Type:

 Sensor Multilevel 

Role Type:

 Reporting Sleeping Slave (RSS) 

Maximum number of devices in group 1:

 3 

Maximum number of devices in group 2:

 3 

Command Class Support/Control 
Mandatory CC Support: 

Association CC, v2 (security 2) 

  

 

 

 

 

Association Group Information CC (security 2) 

  

 

 

 

 

Supervision CC (security 2) 

  

 

 

 

 

Battery CC (security 2) 

  

 

 

 

 

Device Reset Locally CC (security 2) 

  

 

 

 

 

Manufacturer Specific CC, v2 (security 2) 

  

 

 

 

 

Sensor Multilevel CC, V5 (security 2) 

  

 

 

 

 

Version CC, v2 (security 2) 

  

 

 

 

 

Wake UP CC, v2 (security 2) 

  

 

 

 

 

Z-Wave Plus Info CC, v2 

  

 

 

 

 

Power Level CC (security 2) 

  

 

 

 

 

Firmware Update MD CC,v4 (security 2) 

  

 

 

 

 

Transport Service CC, v2 

 

Z-Wave

’s Groups (Association Command Class Version 2) 

G

roup 1 for “LifeLine”: 

Sensor Multilevel CC,V5 (COMMAND_CLASS_SENSOR_MULTILEVEL) 

   

Battery CC (COMMAND_CLASS_BATTERY) 

   

Device Reset Locally CC 

Group 2 for 

“Luminance Report”: 

   

Sensor Multilevel CC, V5 (COMMAND_CLASS_SENSOR_MULTILEVEL) 

Group 2 will send 

“Luminance Report” according to the following conditions: 

   

  The current illuminance changes by +/- 30%. 

  The current illuminance changes by +/-500 (lux). 

  Every time when the Sensor wakes up. 