background image

 

LM-1ZW Ambient Light Sensor 

 

 

Introduction 

LM-1ZW is a Z-Wave Ambient Light Sensor. It monitors your home environment and transmits measured Illuminance (lux), 
to the coordinator in the Z-Wave network. 

The Sensor is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. 

Z-Wave is a wireless communication protocol that uses a low-power RF radio. By taking advantage of the Z-Wave mesh 
network, commands can 

be transmitted to their destination via intermediary “listening” Z-Wave products. 

 

Parts Identification 

1.  Light Sensor / LED Indicator 

Flashes once:

 Transmitting Learning Code 

Light on 1 second:

 Factory Reset / successfully excluded from 

Z-Wave Gateway/Control Panel. 

Flashes 3 times: 

After the sensor has successfully added into 

Z-Wave Gateway/Control Panel.   

2.  Cover-Fixing Screw 

3.  Fixing Hook 

4.  Battery Compartment 

5.  Function Button 

Press once to send a signal to the coordinator. 

Press and hold for 10 seconds to factory reset. 

Press for 3 times within 1.5 seconds to transmit learning code. 

 

Features 

 

Lighting Monitoring

 

 

The sensor measures illuminance to transmit measured data to Z-Wave Control Panel/Gateway regularly.   
Illuminance reading is transmitted every 1minute. 
The sensor will also transmit signal automatically when: 

 

The current illuminance changes by +/- 30%. 

 

The current illuminance changes by +/-500 (lux) 

 

The illuminance detection range is 0~180000(lux) 

 

Battery and Low Battery Detection 

 

The sensor uses one CR123A 3V Lithium battery as its power source.   

 

The sensor features Low Battery Detection function. When the battery voltage is low, the sensor will transmit Low 
Battery signal to the Gateway/Control Panel. The Sensor will report its battery percentage to the Gateway/Control 
Panel respectively at 100% (voltage 3.2 to 2.85V), 75%(voltage 2.84 to 2.72V), 50%(voltage 2.71 to 2.59V) and 
25% (voltage 2.58 to 2.33V). If the battery voltage is low (25%), a Low Battery signal  will be sent to the Control 
Panel to notify the user. 

 

When changing battery, after removing the old batteries, press the Function Button twice to fully discharge before 
inserting new battery. 

 

Wake Up 

This function uses the Z-Wave Wake Up Command Class. The Wake Up Command Class allows the battery-powered 
Sensor to notify the Control Panel/Gateway that it is awake and ready to receive any queued commands. The wake up 
time  period  is  programmed  automatically  according  to  Control  Panel

’s  setting  when  The  Sensor  is  included.  The 

recommended setting of the wake up time is 60 minutes above. 

 
 
 

Reviews: