MINIMUM INSTALLATION CLEARANCE

I A

The  figure  illustrates  the  minimum  clearance  to  be  left  from
walls and furniture in the room when assembling the fan coil.

INSTALLATION - POSITIONING THE UNIT

I A

Avoid installing the unit:
-  in places exposed to direct sunlight;
-  near sources of heat;
-  in  damp  environments  and  areas  where  there  may  be

contact with water;

- in environments with oil vapour;
-  in environments with high frequency interference.

Make sure:
- the  wall  where  the  unit  is  installed  features  a  suitable

structure and capacity;

-  there are no pipes or wiring in the part of the wall affect-

ed;

-  the wall where the unit is installed is perfectly flat;
-  there  is  sufficient  clearance  around  the  unit  to  allow

proper air circulation at the intake and outlet;

-  the wall where the unit is installed should be an outside

perimeter  wall,  so  as  to  be  able  to  drain  the  conden-
sate outside;

-  in the event of ceiling installation (DLMO or DLIU ver-

sion),  the  air  flow  must  not  be  aimed  directly  towards
people in the room.

INSTALLATION PROCEDURE

I A

The  following  descriptions  of  the  various  assembly  opera-
tions  and  the  corresponding  drawings  refer  to  versions  of
the unit with the fittings on the left.
The  descriptions  of  assembly  operations  for  units  with  the
fittings on the right are identical.
Only the drawings will need to be inverted horizontally.

For  best  installation  results  and  optimum  operating  perfor-
mance,  carefully  observe  the  instructions  provided  in  this
booklet. 
Failure to heed the instructions may cause the equipment to
malfunction. In such cases, the warranty will be void and the
company declines all liability for any damage caused to peo-
ple, animals or things.

Summary of Contents for i-LIFE SLIM 102

Page 1: ...Fan coil with casing or for built in installation with tangential fan and inverter controlled brushless motor EN i LIFE SLIM 102 502 INSTALLATION USER MAINTENANCE MANUAL...

Page 2: ...llation procedure 6 Minimum installation clearance 6 Dismantling assembling the casing 7 Vertical installation 7 Horizontal installation 8 Fixing the front intake grill 8 Front grill safety support as...

Page 3: ...appliance These appliances have been designed for cooling and heating rooms and must be used in applications compat ible with their performance characteristics Incorrect installation adjustment and m...

Page 4: ...SPECIFICATIONS i LIFE SLIM 102 202 302 402 502 Coil water content l 0 47 0 8 1 13 1 46 1 8 Maximum operating pressure bar 10 10 10 10 10 Maximum water inlet temperature C 80 80 80 80 80 Minimum water...

Page 5: ...a macchina XYZ XYZ Codice di identificazione 00123 01 2001 MODELLO 10 20 30 40 50 60 70 Potenza frigorifera kW 12 15 17 34 56 77 84 Potenza termica KW 23 33 43 53 63 65 90 Portata aria mc 330 550 670...

Page 6: ...ion at the intake and outlet the wall where the unit is installed should be an outside perimeter wall so as to be able to drain the conden sate outside in the event of ceiling installation DLMO or DLI...

Page 7: ...ing the mouldings Use the paper template and trace the position of the two fastening brackets on the wall Drill the holes with a suitable drill bit and insert the anchors 2 for each bracket fasten the...

Page 8: ...re available as accessories DLRV versions must not be installed horizontally Carefully check the slope of the drain pipe If the drain line is not sloping downwards water may leak from the line A A B B...

Page 9: ...provided in the bag supplied together with the instruction booklet and the accessories These supports are designed to stop the grill from falling Separate the two clamps open the front grill and comp...

Page 10: ...it the pump underneath the side drain pan for horizontal installation the position of the pump should be determined according to specific needs These pumps are widely available on the market In any ca...

Page 11: ...nd return pipes all the way to the unit so as to prevent condensate from dripping out side of the collection pan insulate the entire condensate pan drain pipe A A FILLING THE SYSTEM I A A Coil vent Wh...

Page 12: ...the Technical Service and using orig inal spare parts when required CLEANING THE OUTSIDE OF THE UNIT I A Before any cleaning and maintenance work disconnect the unit from the mains power supply switch...

Page 13: ...tom edge is correctly fitted in place Never use the appliance without the mesh filter The appliance is fitted with a safety switch that prevents the fan from operating if the panel is not fitted or is...

Page 14: ...d make sure the fan can spin freely The microswitch that stops the fan when opening the filter grill does not close correctly Make sure that when closing the grill the microswitch contact is activated...

Page 15: ...COD C01002328A_02...

Reviews: