Trilogy
®
45 Q-Mode
®
(QE) Series
QE
17
Residential Products Technical Guide
Factory Quality & Industry Certifi cations
All units are built and factory run tested on our Integrated Process
Control Assembly System (IPCS). The IPCS is a unique state of the
art manufacturing system that is designed to assure quality of the
highest standards of any manufacturer in the water-source industry.
Our IPCS system:
- Verifi es that the correct components are being assembled.
- Automatically performs special leak tests on all joints
- Conducts pressure tests
- Performs detailed run test
- Automatically disables packaging for a “failed” unit
- Creates computer database for future service analysis and
diagnostics from run test results
- All refrigerant brazing is done in a nitrogen atmosphere
- All units are deep evacuated to less than 100 microns prior
to refrigerant charging
- All joints are both helium and halogen leak tested to insure
annual leak rate of less than ¼ ounce
• AHRI/ASHRAE/ANSI/ISO 13256-1 certifi ed.
• ETL
listed.
• US EPA “Energy Star” Tier 3 compliant.
Advanced Controls
iGate
®
communicating control provides advanced unit functionality
and comprehensive confi guration, monitoring and diagnostic
capabilities through digital communication links with the variable-
speed fan motor, variable-speed source pump (or modulating valve)
and communicating thermostat or Confi guration/Diagnostic tool.
Trilogy
®
45 Q-Mode
®
Design Features
• 15 temperature sensors/transducers for system protection and
control
• Anti-short cycle and over/under voltage protection
• High pressure, loss of charge, and condensate overfl ow protection
• LED fault and status indication at controller
• Service tool port for optional setup and diagnostics at unit
Field Installed Accessories
• iGate
®
Connect Web-Enabled Communicating, Programmable
Thermostat (AWC99**)
• iGate
®
ClimaZone
TM
Zoning Panel
• Auxiliary Electric Heater
• Earthpure
®
Polarized Media Electric Air Cleaner
• Unit Vibration Isolation Pad
• Unit
Stand
• Secondary Drain Pan (Horizontal Units)
• Service tool/cable/software kit (ASVCT00L01).
Warranty
• ClimateMaster residential class heat pumps are backed by a
ten-year limited warranty on all unit parts, including the following
accessories when installed with ClimateMaster units: Flow
Controllers, Thermostats & Electric Heaters.
• ClimateMaster goes even further to back up its commitment to
quality by including a service labor allowance for the fi rst fi ve
years on unit parts and thermostats, auxiliary electric heaters and
geothermal pumping modules.
• The Optional Extended Factory Service Labor Allowance
Warranty offers additional length of term protection to the
consumer by offsetting service labor costs for 10 years.
9
6
8
4
7
5
3
2
1
10
Exclusive iGate
®
Two-Way Communicating Control to confi gure,
monitor and diagnose AT THERMOSTAT/PC SERVICE TOOL
vFlow
®
Internal Variable Water Flow System with Variable Speed
Internal Flow Center for optimized effi ciency and reliability
Mitsubishi Inverter Variable Speed Compressor with dual-level
isolation for ultra-quiet and high-effi ciency operation
Emerson UltraTech
®
Variable-Speed Communicating Fan Motor
with soft start and constant CFM control
Microchannel Aluminum Air Coils to resist formicary corrosion
Foil-Faced Insulation in the blower section and fully insulated
compressor section conform to ASHRAE 62 specifi cations
Two-inch high-effi ciency MERV 11 Filter (standard) or EarthPure
®
Air Cleaner for high quality indoor air
Two-Section Swing-out Control Box design provides wide-open
service access
Water Schrader Ports located on corner post to easily
read pressure drop across water heat exchanger for easy
troubleshooting
Heavy Gauge Galvanized Steel Cabinet is epoxy powder-coated in
a durable and attractive black matte fi nish with stainless steel front
access panels
Designed for External P-trap to eliminate internal drain-line
cleanouts
11
4
5
6
7
12
10
11
2
8
9
1
3