T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y
Rooftop (TRE) Series
R e v. : O c t o b e r 7 , 2 0 1 9
3
c l i m a t e m a s t e r. c o m
Model Nomenclature
Curb (TRE & ERV Unit Nomenclature)
T R E 0 3 6
H
D
1
D
A A A A S
1 2 3
4 5 6
7
8
9
10 11 12
13
14 15
TRANQUILITY
®
ROOFTOP UNIT
SERIES
UNIT SIZE
REVISION LEVEL
VOLTAGE
CONTROLS
CABINET & FILTER
HEAT EXCHANGER OPTIONS
A = NONE
AIR DAMPER OPTIONS
A = NONE
POWER TERMINATION
B = DISCONNECT
C = DISC GFI OUTLET
STANDARD
036
048
060
072
096
120
144
168
BLOWER DRIVE PACKAGE
D = DXM2
M = DXM2 w/LON
P = DXM2 w/MPC
B = MANUAL ADJUSTABLE FRESH AIR DAMPER
S = STANDARD
240
ETL APPROVED
USA & CANADA
A = STANDARD RPM & STANDARD MOTOR
B = LOW RPM & STANDARD MOTOR
C = HIGH RPM & STANDARD MOTOR
D = STANDARD RPM & LARGE MOTOR**
E = HIGH RPM & LARGE MOTOR**
D = CIRCUIT BREAKER
E = CIRCUIT B GFI OUTLET
C = MOTORIZED FRESH AIR DAMPER
OPTION
RANGE
2”, (50mm) FILTER
MERV 8
4”, (50mm) FILTER
MERV 8
4”, (100mm) FILTER
MERV 13
THROWAWAY FILTER OPTIONS
1
B
C
3
D
E
EXTENDED
RANGE
STANDARD
RANGE
YES
NO
NO
NO
YES
NO
NO
NO
YES
YES
NO
NO
NO
YES
NO
NO
NO
YES
F = MODULATING ENTHALPY ECONOMIZER
A = HOT GAS BYPASS (on lead circuit only; std with
ClimaDry
®
option position 12)
B-Z = SPECIALS
NON-COATED AIR COILS
E-COATED AIR COILS
C
T
N
S
A
U
J
W
STANDARD
MOTORIZED VALVE
COPPER (CU)
COAX
CUPRO-NICKEL (CN)
COAX
E
P
D
F
CLIMADRY
®
H
Z
G
Y
INTERNAL
SECONDARY PUMP
*
COPPER (CU)
COAX
CUPRO-NICKEL (CN)
COAX
REHEAT COIL
3-WAY MOTORIZED VALVE
PROPORTIONAL CONTROL
CIRCULATING PUMP
PUMP CONTACTOR
HOT GAS BYPASS
DMX2 CONTROL
CLIMADRY
®
OPTION COMPONENTS
N = 575/60/3
D= CURRENT REVISION
F = 460/60/3
H = 208-230/60/3 (FACTORY WIRED 208)
A C U R B
A A A A
1 2 3 4 5
9 10 11
12
Model Type
TRE 036 - 072 Standard Curb =
AAA
CURB TYPE and/or Cabinet Size
Curb Constructions
B = Standard 24” High - TRE, ERD, ERS
D = 14” High Curb for ERO Stand Alone ERV
E = 24” High Curb for ERO Stand Alone ERV
C = Horizontal Discharge/RH & LH (TRE Only)
Field Changeable - Supply and Return
TRE 168 - 240 Standard Curb =
Stand Alone 300 - 1000 cfm B =
Stand Alone 1200 - 2800 cfm D =
Stand Alone 1200 - 2000 cfm C =
Stand Alone 2000 - 3600 cfm E =
Stand Alone 3000 - 4600 cfm F =
Stand Alone 4600 - 6200 cfm G =
Stand Alone 6000 - 8000 cfm H =
Stand Alone 8000 - 1200 cfm J =
AAC
EVB
EVD
EVE
EVF
EVG
EVH
EVJ
EVC
TRE 096 -144 Standard Curb =
AAB
G
8
Revision Level
G
= Current Revision
A = Standard 14” High - TRE, ERD, ERS
R T
6 7
ACURB
= Curb
Series Type
RT =
EV =
TRE Series
Stand alone ERV Series
A
13
Curb Options
B = Welded
C = Welded Vibration Isolation (TRE only)
A = Knocked Down
S = Standard
N
14
Not Used
S
15
Standard
Note: Horizontal curb adapter for TRE only.
End return RH or LH supply, field changable.
Fits on top of digit 12 option A or B.
Digit 13 can be option A or C.