Installation Manual 

97B0055N03

Rev.: 2/24/14

ATC32U02 iGate

 Communicating, 

Programmable Thermostat

Table of Contents

Caution:

These instructions are intended to be used by the installer or service personnel.  End users are NOT advised to change or 
modify any of these settings.  Doing so may cause the equipment to stop working properly and/or may void the warranty on 
both the thermostat and the equipment.

Section Title 

Page

 

 

Safety/Installation Considerations  

  3

1.0  

User Menu Settings  

  4

2.0  

Installer Menu Settings  

  6

 

2.1  

Installer Menu Settings Access  

  6

 

2.2  

Thermostat Confi guration  

6

3.0  

System Confi guration  

7

 3.1 

  Airfl ow Selection  

7

 

3.2  

Option Selection  

7

 

3.3  

Unit Confi guration  

8

 

3.4  

Pump Confi guration  

8

 

3.5  

Valve Confi guration 

9

 

3.6  

Multi-Unit Confi guration  

9

4.0  

Accessory Confi guration  

10

 

4.1  

Air Filter  

10

 4.2 

  Humidifi er  

10

 

4.3  

UV Lamp  

10

Section Title 

Page

 

4.4  

Air Cleaner 

10

5.0  

Input Dealer Information  

10

6.0  

Humidity Confi guration  

11

7.0  

Temperature Algorithm  

11

8.0  

Demand Reduction Confi guration  

12

9.0  

Service Mode  

12

 

9.1  

Manual Operation  

12

 

9.2  

Control Diagnostics  

12

 

9.3  

Dipswitch Confi guration  

13

 

9.4  

Fault History  

13

 

9.5  

Clear Fault History  

14

 

9.6  

Multi-Unit Diagnostics  

14

 

9.7  

Multi-Unit Fault Information  

15

10.0  

Restore Defaults  

15

11.0  

Revision History  

16

Summary of Contents for iGate ATC32U02

Page 1: ...Access 6 2 2 Thermostat Configuration 6 3 0 System Configuration 7 3 1 Airflow Selection 7 3 2 Option Selection 7 3 3 Unit Configuration 8 3 4 Pump Configuration 8 3 5 Valve Configuration 9 3 6 Multi...

Page 2: ...This page was intentionally left blank...

Page 3: ...ed for proper operation and mark wall through 2 mounting holes 5 Drill two 3 16 in mounting holes in wall where marked Note Mounting holes on thermostat are designed to fit on a horizontal J box 6 Sec...

Page 4: ...ntrol algorithm must be configured for Differential control to access the Differential settings by installer 1 1 2 HUMIDITY OFFSET If you find that the Humidity level displayed on the thermostat does...

Page 5: ...ature at the time when Demo Mode is entered The unit will operate in heating or cooling based upon the following algorithm 1 3 3 EXITING DEMO MODE To exit demo mode remove power to the thermostat Star...

Page 6: ...nds while the thermostat is in OFF Mode 2 2 THERMOSTAT CONFIGURATION Upon initial power up the communicating thermostat will prompt the installer for the thermostat configuration settings Model number...

Page 7: ...center button to select each item Airflow Settings defaults stored in control valid range obtained from control in 25 CFM increments Blower Off Delay default 60 seconds valid range 0 to 255 seconds in...

Page 8: ...ELECT OPTION PREVIOUS SAVE 3 4 PUMP CONFIGURATION vFlow vs internal flow control pump can be controlled either through temperature differential Delta T or can be set to specific speed fixed of full sp...

Page 9: ...guration instructions MODULATING VALVE CONFIGURATION OFF POSITION 0 0 VALVE CONTROL DELTA T HEATING DELTA T 7 F COOLING DELTA T 10 F MAXIMUM HEAT LWT 80 F MINIMUM COOL LWT 40 F PREVIOUS SELECT For cer...

Page 10: ...s Calendar Time default Off valid range Off 3 to 24 months in 3 month increments 4 3 UV LAMP This feature displays an alert to remind the user to change the UV lamps after the selected time has passed...

Page 11: ...shooting the temperature setpoint adjust the Anticipator value up to reduce thermostat sensitivity If the thermostat is undershooting the temperature setpoint adjust the Anticipator value down to incr...

Page 12: ...he center button to save changes Smart Heat Staging default Off options OFF 5 120 minutes in 5 minute increments 7 6 ELECTRIC HEAT LOCKOUT Electric heat lockout keeps electric heat turned off if the o...

Page 13: ...1 ON FACTORY SETTING 2 OFF HWG TEST OFF 3 OFF HWG SP 125 4 OFF HWG DISABLED JW3 LT1 SETTING WELL PREVIOUS 9 3 DIPSWITCH CONFIGURATION Dipswitch Configuration mode allows the service personnel to view...

Page 14: ...7 9 4 4 Configuration Conditions Displays the status of all dipswitch settings that were recorded at the time the fault occurred NOTE If multiple units are connected to one thermostat refer to sectio...

Page 15: ...ected directly to the ATC thermostat or connected to one another in series as shown by the figure below CONTROL DIAGNOSTICS TT026 S N 1 2 3 4 TT026 S N 5 6 7 8 TT038 S N 9 0 1 2 PREVIOUS SELECT TT038...

Page 16: ...ress warran ties and do not form the basis of any bargain between the parties but are merely ClimateMaster s opinion or commendation of its products The management system governing the manufacture of...

Reviews: