cliMATE CM-8000E Manual Download Page 10

EVAPORATIVE AIR COOLER CM-8000E 

 

www.climateplus.ae 

 

To loosen 4 screws of posterior lateral plate (as picture 7) 

1.

 

Remove the two dust networks, then raise up posterior lateral plate with hands (as picture 8) 

2.

 

Put up the posterior lateral plate after pulling it  out, finally, it is removed (as picture 9) 

3.

 

Follow these steps to reverse the procedure for installation.        

 

Water in / out diagramed 

 

Picture 10                        

  Picture 11                           Picture 12                    

 

  Picture 13   

 
Water in 

1.

 

Pull the water inlet (as picture 10) 

2.

 

Inward water (as picture 11) 

3.

 

Water in/out diagramed (as picture 13) 
 

Water out 

Counterclockwise rotation of the valve cover by hand and get it out, after all the water out, the drain value in 
a clockwise rotation into the drain valve scat, until the close date. (as picture 12). 
 

Warning 

1)

 

Air cooler should be used environment of adequate ventilation, be avoided in a closed environment, so as 
to achieve better cooling effect. 

2)

 

The brake of caster brake should be used when the air cooler is running, to prevent it to slide. 

3)

 

The pump automatically shut down when the air-cooler runs dry, you should supply water in time, before 
adding water to stop air cooler running, and turn off the power, and water should not exceed the 
maximum water level. 

 
 

 

-08-

 

Summary of Contents for CM-8000E

Page 1: ...EVAPORATIVE AIR COOLER CM 8000E www climateplus ae...

Page 2: ...as standard a float valve keeps the reservoir full continuously If filled manually the big 60 Litre capacity reservoir ensures hours of interrupted operation There is a digital level indicator to quic...

Page 3: ...ion 310W Fan Style Axial Water Consumption 4 6L H Water Capacity 60L Dimension L W H 890x490x1400mm Weight 32kg Effective Cooling Area 30 55m2 KT 1E 3N TECHNICAL FEATURE Preface Thank you for your tru...

Page 4: ...principle 2 Workplace used for 2 Display board 3 Function for buttons 3 Installation operation 4 Wiring diagram 5 Installation of caster and caster frame diagram 6 Disassembly6 diagram for posterior...

Page 5: ...is designed with special angle when the hot air passes the surface of wet curtain with water it will lose considerable heat and let it cool also the air is filtered finally the air become cool comfort...

Page 6: ...off the swing direction 5 Anion key Press this key start the function for anion 6 Timer key Press this key activate timer function 2 Remote controller 1 On off the cooler will stands by turn off 2 Coo...

Page 7: ...on the swing indicator light when it turns off the swing light goes out 5 anion Press the key when machine work to turn the device which can produce anion on or off or press the speed key on the remo...

Page 8: ...EVAPORATIVE AIR COOLER CM 8000E www climateplus ae Wiring Diagram 06...

Page 9: ...of tank base the caster with break should be installed on the outlet side and to make sure casters and tank base contacted close as picture 5 3 Caster frame with caster fixation to the button of the...

Page 10: ...Water in out diagramed as picture 13 Water out Counterclockwise rotation of the valve cover by hand and get it out after all the water out the drain value in a clockwise rotation into the drain valve...

Page 11: ...9 Clean air filter and wet curtain regular by tap water and soft brush 10 When the air cooler failure do not attempt to deal with not professionals 11 When you stop using air cooler empty the water ta...

Page 12: ...e Remedy It doesn t work Power off Check the supply Fuse break Change fuse Pcb failure Change pcb No air flow Keys for on off Change panel Motor trouble Change motor Pcb failure Change pcb No cooling...