Click RF PiLOT Installation Manual Download Page 9

15

14

T1

T2

T1

T2

T1

T2

Programming - Initial Setup

tu 01.03.11                  12:54

Hours:

12

Minutes:

54

EXIT                              SAVE

Fig. 3

To move in the 

Programming

 menu use up & down on the dial to select 

Date and time

 (text in white). 

Confirm using the T1 button (Fig.1). 

Here you can set the current time, time format (12/24), date and day of the week. 
- Using up & down on the dial, select the element to be adjusted (Time/Format etc.) highlighted in white.
- Use the right of the dial to access the menu to adjust the parameters (Fig.2). 
- Use up & down on the dial to select the required section. The left & right of the dial are used to adjust 
  the values.
- Save the settings by pressing T1.

Date and Time

Time:

12:54

Format:

12

Date:

01 Mar 2011

Day in week:

Tuesday

EXIT                              SAVE

Fig. 2

Language

Date and time

Actuators

Rooms

Scenes

Favourites

Device reset

EXIT                          SELECT

Fig. 1

T1

T2

T1

T2

T1

T2

The RF Pilot automatically arranges the names of Rooms 1-10 in order. 
Within the programming menu, you can rename or reset the name to factory conditions. Once the room 
is renamed it will replace the room with number in the room menu.
In the Programming menu, using up & down on the dial select Rooms. Press T1 to select (Fig.1). 
Use the up and down dial to highlight the Room that you want to rename (1-10). 
Select using T1 (Fig.2). The menu is displayed (Fig.3)    

    

Rename

      

  

Reset

 

Note: The selected room is highlighted white. Any rooms with actuators assigned are shown in blue (unless selected). Rooms without assigned 
actuators are shown in grey.

Rooms

Language

Date and time

Actuators

Rooms

Scenes

Favourite

Device reset

EXIT                           SELECT

Fig. 1

tu 01.03.11                  12:54

Room 1

Room 2

Room 3

Room 4

Room 5

Room 6

Room 7

EXIT                           SELECT

Fig. 2

tu 01.03.11                  12:54

Name:

Room 1

Rename

Reset

EXIT                           SELECT

Fig. 3

Programming - Rooms

Rooms

Initial Setup - 

Date & Time

Summary of Contents for RF PiLOT

Page 1: ...4 0 C h a n n e l R e m o t e C o n t r o l W i t h O L E D D i s p l a y Installation Manual 26 03 2014 16 29 23...

Page 2: ...junction with other RF Control devices the RF Pilot offers you Comfortable handheld control Activation of household appliances and devices Light dimming and creation of light scenes Control of blinds...

Page 3: ...d you become aware of any signs of damage deformation malfunction or of any missing parts do not install this product and return it to the vendor After the expiry of its service life the product and a...

Page 4: ...immediately after switching on the RF Pilot Range up to 200m Operates on the frequency 868 5 Mhz Colour anthracite Battery supply 2 x AAA with life cycle up to 3 years Other data Operating temperatur...

Page 5: ...ntrol devices with 0 1 10V dimmable input Analogue Actuator Dim Pack DIM 6 2000Va dimming pack with 0 1 10V input and momentary switch input de rate for LED loads Becomes wireless when used in conjunc...

Page 6: ...ll remain After inserting the batteries the RF Pilot name and the firmware version will appear on the initial screen as shown above To set the Date and Time elements see page 14 Current Temperature Di...

Page 7: ...cenes The 10 most commonly used actuators and scenes can be selected in to the favourites quick control menu The favourites appear on the initial screen and activated with just a couple of clicks Step...

Page 8: ...hilst in the Control Menu The programming menu can only be accessed from the control menu with pressing the left side of the dial and T1 together Programming Menu Language setting With language highli...

Page 9: ...ourites Device reset EXIT SELECT Fig 1 T1 T2 T1 T2 T1 T2 The RF Pilot automatically arranges the names of Rooms 1 10 in order Within the programming menu you can rename or reset the name to factory co...

Page 10: ...1 12 54 Name Room 1 Rename Reset EXIT SELECT Fig 5 T1 T2 T1 T2 T1 T2 T1 T2 In the Programming Menu select Actuators Fig 6 Press the T1 button to enter the menu Add To add an actuator to the RF Pilot C...

Page 11: ...oom 7 EXIT Allocate Fig 3 Programming Actuators Rename Fig 6 Used to change the name of the actuator the name will then be displayed in the menu list under the Room Control function Using up down on t...

Page 12: ...Range test Control Remove EXIT SELECT Fig 4 T1 T2 T1 T2 T1 T2 tu 01 03 11 12 54 EXIT START Fig 3 Memory 1 40 Type address RFSA6x 012345 Room Lounge Name Lamp EXIT SELECT Fig 2 tu 01 03 11 12 54 Add A...

Page 13: ...g Actuator Functions Description Turn On Actuator switched On Turn Off Actuator switched Off Brightness 0 Brightness setting within the range 0 100 10 steps using left right buttons Slowly On Graduall...

Page 14: ...11 12 54 Turn On Turn Off Brightness 0 White RGB BACK PROCEED Fig 1 T1 T2 tu 01 03 11 12 54 Turn On Turn Off Brightness 0 White RGB BACK PROCEED Fig 2 T1 T2 T1 T2 Select the required function highlig...

Page 15: ...ene 3 Scene 4 Scene 5 Scene 6 Scene 7 EXIT SELECT Fig 2 tu 01 03 11 12 54 Name Scene 1 Rename Commands Reset BACK PROCEED Fig 3 Programming Scenes Rename Fig 4 Used to change the name of the scene the...

Page 16: ...T Fig 3 Programming Scenes Scenes Commands Scenes Commands continued T1 T2 Command 1 10 Room Unassigned Actuator Unassigned Action Unassigned BACK ASSIGN Fig 2 T1 T2 tu 01 03 11 12 54 Turn On Turn Off...

Page 17: ...igned Action Unassigned BACK ASSIGN Fig 1 Commands LED RGB controller After each actuator and function has been added to a command the screen will move to the next command 3 10 etc automatically Fig 1...

Page 18: ...nguage Date and time Actuators Rooms Scenes Favourite Device reset EXIT SELECT Fig 1 T1 T2 tu 01 03 11 12 54 Name Favourite 1 Assign Cancel BACK SELECT Fig 3 Programming Favourite T1 T2 Assign Used to...

Page 19: ...1 12 54 Reading Scene 2 Scene 3 Scene 4 Scene 5 Scene 6 Scene 7 EXIT SELECT Fig 7 T1 T2 tu 01 03 11 12 54 Turn On Turn Off EXIT ASSIGN Fig 4 T1 T2 tu 01 03 11 12 54 Centre Light F Favourite 2 Favourit...

Page 20: ...avourite 5 Favourite 6 Favourite 7 Temp 23C MENU Fig 3 tu 01 03 11 12 54 Favourite 1 Favourite 2 Favourite 3 Lamps Favourite 5 Favourite 6 Favourite 7 Temp 23C MENU Fig 4 Initial Screen Quick Control...

Page 21: ...actuator s has have not confirmed executing the command please repeat the command If the error persists The actuator has accepted and executed the command RF Pilot has not detected any execution feed...

Page 22: ...posed of in accordance with local environmental regulations Batteries accumulators Batteries must never be disposed within household waste They may contain poisonous substances harmful to the environm...

Page 23: ...35 36 37 38 39 40 Number Location Identification 12 Chars Name of Controlled Load 12 Chars Actuator Part No Actuator Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 A4 version can be downl...

Page 24: ...Notes Notes...

Page 25: ...fordshire B79 7XB Tel 01827 63454 Fax 01827 63362 sales scolmore com www scolmore com V10 0 18 Corrig Road Sandyford Industrial Estate Dublin 18 Ireland Tel 353 1 2811 122 Fax 353 1 2811 224 sales cli...

Reviews: