Power cables
Power input and throughput cables must be rated 16A minimum, have three conductors 1.5 mm² (16 AWG) minimum
conductor size and an outer cable diameter of 5 - 15 mm. Cables must be hard usage type (SJT or equivalent) and heat-
resistant to 90°C minimum. In the EU the cable must be HAR approved or equivalent.
If you install a power plug on the power cable, install a grounding-type (earthed) plug that is rated 16A minimum. Follow
the plug manufacturer’s inst
ructions. Table 1 shows standard wire color-coding schemes and some possible pin
identification schemes; if pins are not clearly identified.
Wire Color (EU models)
Wire Color (US models)
Conductor
Symbol
Brown
Black
Live
L
Blue
White
Neutral
N
Yellow/Green
Green
Ground (earth)
or
Daisy-chain power to other devices
Warning! Do not connect more than three fixtures in total in one interconnected chain. Power can be relayed to another
device via the PowerCON TRUE 1 ® throughput socket.
If you daisy-chain the fixtures in a chain so that they all draw AC mains power via the first fixture, certain points must be
respected:
A heavy duty, three-conductor, 16 AWG or 1.5 mm2 cable with SJT or equivalent cable jacket must be used to connect the first
fixture to AC mains power. PowerCON TRUE1 ® connectors must be used to draw
AC mains power from the fixtures power throughput socket and yellow PowerCON TRUE 1 ® connectors must be used to supply
power at the fixture’s power input sockets.
Data link
A DMX 512 data link is required in order to control a fixture via DMX. The fixture has 5-pin XLR connectors for DMX data
input and output. The pin-out on all connectors is pin 1 = shield, pin 2 = cold (-), and pin 3 = hot (+) Pins 4 and 5 in the 5-
pin XLR connectors are not in use.
Tips for reliable data transmission
To connect the fixture to data:
1. Connect the DMX data output from the controller to the 5-pin XLR connector of the nearest fixture.
2. Connect the DMX output of the first fixture to the DMX input of the next fixture and continue connecting fixtures.
Summary of Contents for POSEIDON Wash XL
Page 1: ...POSEIDON Wash XL manual ...
Page 3: ...Dimensions in millimeters ...
Page 6: ...Fixture overview ...
Page 32: ...photometrics ...
Page 33: ...circuit connection diagram ...
Page 36: ...Positioning ...
Page 37: ...Layout ...
Page 38: ...POSEIDON Wash XL ...