power cables

Power input and throughput cables must be rated 20A minimum, have three conductors 1.5 mm² (16 AWG) 
minimum conductor size and an outer cable diameter of 5 - 15 mm. Cables must be hard usage type (SJT or 
equivalent) and heat- resistant to 90°C minimum. In the EU the cable must be HAR approved or equivalent.

If you install a power plug on the power cable, install a grounding-type (earthed) plug that is rated 20A 
minimum. Follow the plug manufacturer’s instructions. Table 1 shows standard wire color-coding schemes 
and some possible pin identification schemes; if pins are not clearly identified.

Relaying power to other devices

Warning! Do not connect more than ten fixtures in total to AC mains power in one interconnected chain. 
Power can be relayed to another device via the 

 throughput socket.

®

PowerCON TRUE 1 

If you daisy chain the fixtures in a chain so that they all draw AC mains power via the first fixture, certain 
points must be respected:

2

• A heavy duty, three-conductor, 16 AWG or 1.5 mm  cable with SJT or equivalent cable jacket must be used to 
connect the first fixture to AC mains power.

• 

 connectors must be used to draw AC mains power from the fixtures power throughput 

 

®

PowerCON TRUE 1

sockets and yellow 

 connectors must be used to supply power at the fixture’s power input 

®

PowerCON TRUE 1 

sockets.

• No matter what the AC mains power voltage is, do not connect more than ten the fixture in total ( including 
the first fixture) to AC mains power in one interconnected daisy chain using power input and through out 
connectors.

A DMX 512 data link is required in order to control a fixture via DMX. The fixture has 5-pin XLR connectors for 
DMX data input and output. The pin-out on all connectors is pin 1 = shield, pin 2 = cold (-), and pin 3 = hot (+) 
Pins 4 and 5 in the 5-pin XLR connectors are not used.

 tips for reliable data transmission

To connect the fixture to data:

1. Connect the DMX data output from the controller to the 5-pin XLR connector of the nearest fixture.

2. Connect the DMX output of the fixture closest to the controller to the DMX input of the next fixture and 

continue connecting fixtures output to input.

Wire

 

Color

 (

EU

 

models

)

Wire

 

Color

 (

US models

)

Conductor

Symbol

Brown

Black

Live

L

Blue

White

Neutral

N

Yellow

/

Green

Green

Ground

 (

earth

)

      

or

DATA

 

LINK

Table 1 : Wire

 

color

-

coding

 

and

 

power

 

connections

Summary of Contents for SPECTRUM P2 VARI-WHITE

Page 1: ...manual V1 0 May 2018 WWW CLF LIGHTING COM SPECTRUM P2 VARI WHITE SP EC TR UM P2 V W ...

Page 2: ... Fastening the fixture to a flat surface 7 Setup 8 Control panel and menu navigation 8 DMX address setting 8 Control Mode 9 Static Color options 10 Auto Show 11 Master Slave 11 Personality 11 Dimmer speed 11 Dimmer curve 11 Key Lock 11 Refresh rate 11 LCD brightness 11 DMX HOLD 11 Dimmer mode 12 Information 12 Software type 12 Usage time 12 Temperature 12 UID 12 Factory reset 12 DMX protocols 13 O...

Page 3: ...Dimensions All dimensions are in millimeters WWW CLF LIGHTING COM 1 0 SPECTRUM P2 V W 106 260 290 Φ203 180 ...

Page 4: ...d observe all warnings in this manual and printed on the fixture If you have questions about how to operate the fixture safely please contact your supplier PROTECTION FROM ELECTRIC SHOCK l Disconnect the fixture from AC power before removing or installing any cover or part and when not in use l Always ground earth the fixture electrically l Use only a source of AC power that complies with local bu...

Page 5: ... onto any optical component besides the optional CLF Yara filters l Do not modify the fixture in any way not described in this manual l Do not use fixture on a dimmer PROTECTION FROM INJURY l Do not look continuously at LEDs from a distance of less than 3 meters from the front surface of the fixture without protective eyewear such as shade 4 5 welding goggles At less than this distance the LED emi...

Page 6: ...tachment point LCD Display 5P DMX input 5P DMX output AC mains power throughput AC mains power input G Clamp with Quicklock 875760 Optional Omega bracket with Quicklock 520114 Optional 3P DMX input optional CLF 13 453 3P DMX output optional CLF 13 454 P2 VARI WHITE SPECTRUM ...

Page 7: ...t breaker and ground fault earth fault protection Warning Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixtures can easily be disconnected from power Important Do not insert or remove live connectors to apply or cut power as this PowerCON TRUE 1 may cause arcing at the terminals that will damage t...

Page 8: ...ust be used to connect the first fixture to AC mains power connectors must be used to draw AC mains power from the fixtures power throughput PowerCON TRUE 1 sockets and yellow connectors must be used to supply power at the fixture s power input PowerCON TRUE 1 sockets No matter what the AC mains power voltage is do not connect more than ten the fixture in total including the first fixture to AC ma...

Page 9: ...face can support at least 10 times the weight of all fixtures and equipment to be installed on it Warning The supporting surface must be hard and flat or air vents in the base may be blocked which will cause overheating Fasten the fixture securely Do not stand it on a surface or leave it where it can be moved or can fall over Attach a securely anchored safety cable to the safety cable attachment p...

Page 10: ... one level in the menu structure press MODE Holding down the UP and DOWN button for more than 3 seconds the MENU display will rotate 180 Menu Manual Enter Test mode DMX address setting The DMX address also known as the start channel is the first channel used to receive instructions from the controller For independent control each fixture must be assigned its to a separate channel The DMX address c...

Page 11: ...WWW CLF LIGHTING COM 9 0 Control mode DMX control mode is selected in the CONTROL MODE menu The fixture has 5 DMX control modes 2ch 3ch 4ch 5ch 6ch Dimmer Cool white Warm white CCT Strobe Fade ...

Page 12: ...scroll through the options 2 CCT Easy color choice between 2800K warm white to 6000K cood white 3 Manual Color Mix your own color with each warm white and cool white value seperately Cool White Warm white CW WW Dimmer 000 255 Dimmer CW 000 255 Dimmer Cool white WW 000 255 Dimmer Warm white Strobe 00 20 Strobe 00 20Hz 2800 K 4500 K 3200 K 4800 K 3500 K 5000 K 3800 K 5500 K 4000 K 6000 K ...

Page 13: ...Auto program 2 3 Auto 3 Auto program 3 Here you can set all functions for the fixture personality Dimmer Speed Normal Smooth 1 Smooth 2 Smooth 3 Smooth 4 Dimmer curve linear Square law INV Square law S Curve Special KEY Lock Locks all the button functions Standard unlocking password is MODE UP MODE DOWN MODE UP MODE DOWN ENTER Refresh rate Controls the Flicker frequency of the fixture 600 1200 240...

Page 14: ...tensity control is coarser at low levels and finer at high levels l S CURVE light intensity control is finer at low levels and high levels and coarser at medium levels l Special the light intensity was linear increase with DMX value and light intensity control is finer at low level with DMX values decrease the dimmer speed will also has effect on it Whichever DIMMER CURVE option you select you can...

Page 15: ... 255 0 100 4 CCT 000 009 010 255 No function 6000K 2800K 5 Strobe 000 024 025 064 065 069 070 084 085 089 090 104 105 109 110 124 125 129 130 144 145 149 150 164 165 169 170 184 185 189 190 204 205 209 210 224 225 229 230 244 245 255 Shutter open Strobe 1 fast slow Shutter open Strobe 2 opening pulse fast slow Shutter open Strobe 3 closing pulse fast slow Shutter open Strobe 4 random strobe fast s...

Page 16: ...09 210 224 225 229 230 244 245 255 Shutter open Strobe 1 fast slow Shutter open Strobe 2 opening pulse fast slow Shutter open Strobe 3 closing pulse fast slow Shutter open Strobe 4 random strobe fast slow Shutter open Strobe 5 random opening pulse fast slow Shutter open Strobe 6 random closing pulse fast slow Shutter open Strobe 7 burst pulse fast slow Shutter open Strobe 8 random burst pulse fast...

Page 17: ...e law INV Square law S Curve Special Default linear Key Lock ON OFF Default OFF Refresh rate 600 1200 2400 4800 Default 4800 LCD brightness Level 1 10 DMX HOLD DMX HOLD NO DMX HOLD Default DMX HOLD 4 STATIC COLOR Fixed color CW WW CW WW Default CW WW CCT 2800K 3200K 3500K 3800K 4000K 4500K 4800K 5000K 5500K 6000K Default 4000K Manual color Dimmer 0 255 Default 255 CW 0 255 Default 255 WW 0 255 Def...

Page 18: ...r CLF 14 017 9 Power supply CLF 14 015 10 Power supply support bracket CLF 14 007 11 Case body CLF 14 001 12 Display board CLF 19 005 13 Display sticker CLF 19 004 14 Acrylic display support CLF 14 012 15 PowerCON TRUE1 input socket CLF 14 027 16 PowerCON TRUE1 output socket CLF 14 028 17 DMX 5 pin male chassis part waterproof CLF 14 032 18 DMX 5 pin female chassis part waterproof CLF 14 031 19 Va...

Page 19: ... materials 100 mm from fixture Minimum distance to illuminated surfaces 200 mm from fixture Connections AC power input PowerCON TRUE 1 input socket AC power throughput PowerCON TRUE 1 output socket DMX data in out 5 pin locking XLR 3 pin optional with CLF 13 453 CLF 13 454 Electrical AC power 100 240 V nominal 50 60 Hz Maximum total power consumption 110 W Power supply unit Auto ranging electronic...

Page 20: ...WWW CLF LIGHTING COM CLFLIGHTING SPECTRUM P2 VARI WHITE ...