CLF Lighting SPECTRUM P2 VARI-WHITE Manual Download Page 5

WWW

.

CLF

-

LIGHTING

.

COM

3

.

0

Do not expose the fixture to rain or moisture

l

Refer any service operation not described in this manual to a qualified technician.

l

Socket outlets used to supply the fixture with power or external power switches must be located near the fixtures and 

easily accessible so that the fixtures can easily be disconnected from power.

PROTECTION FROM  BURNS AND FIRE

l

Do  not  operate  the  fixture  if  the  ambient  temperature  (Ta)  exceeds  40°C.

l

The  exterior  of  the  fixture  becomes  hot  during  use. Avoid  contact  by  persons  and  materials.                            

Allow  the  fixture  to  cool  for  at  least  10  minutes  before  handling.

l

Keep  all  combustible  materials  (e.g.  fabric,  wood,  paper)  at  least  100  mm   away  from  the  fixture.

l

Keep flammable materials well away from the fixture.

l

Ensure that there is free and unobstructed airflow around the fixture.

l

Do not illuminate surfaces within 200 mm  of the fixture. 

l

Do not attempt to bypass thermostatic switches or fuses.

l

If you relay power from one fixture to another using power throughput sockets, do not connect more than ten the 

fixture in total to each other in an interconnected chain.

l

Connect only other the fixture to fixture power throughput sockets. Do not connect any other type of device to these 

sockets.

l

Do not connect any other type of device to these sockets.

l

Do not stick filters, masks or other materials onto any optical component, besides the optional CLF Yara filters.

l

Do not modify the fixture in any way not described in this manual.

l

Do not use fixture on a dimmer.

PROTECTION FROM INJURY

l

 

Do not look continuously at LEDs from a distance of less than 3 meters from the front surface of the fixture without 
protective eyewear such as shade 4-5 welding goggles. At less than this distance, the LED emission can cause eye 
injury or irritation. At distances of 3 meters and above, light output is harmless to the naked eye provided that the 
eye’s natural aversion response is not overcome.

l

 Do not look at LEDs with magnifiers, telescopes, binoculars or similar optical instruments that may concentrate the 

light output.

l

 Ensure that persons are not looking at the LEDs from within 3 meters when the product lights up suddenly. This can 

happen when power is applied, when the product receives a DMX signal, or when SERVICE menu items are 
selected.

l

 Fasten the fixture securely to a fixed surface or structure when in use. 

l

 Ensure that any supporting structure and/or hardware used can hold at least 10 times the weight of all the devices 

they support.

l

 Allow enough clearance around the fixture to ensure that it cannot collide with an object or another fixture when it 

moves.

l

 Check that all external covers and rigging hardware are fastened securely.

l

 Block access below the work area and work from a stable platform whenever installing, servicing or moving the 

fixture.

l

Do not operate the fixture with missing or damaged covers, shields or any optical component.

Summary of Contents for SPECTRUM P2 VARI-WHITE

Page 1: ...manual V1 0 May 2018 WWW CLF LIGHTING COM SPECTRUM P2 VARI WHITE SP EC TR UM P2 V W ...

Page 2: ... Fastening the fixture to a flat surface 7 Setup 8 Control panel and menu navigation 8 DMX address setting 8 Control Mode 9 Static Color options 10 Auto Show 11 Master Slave 11 Personality 11 Dimmer speed 11 Dimmer curve 11 Key Lock 11 Refresh rate 11 LCD brightness 11 DMX HOLD 11 Dimmer mode 12 Information 12 Software type 12 Usage time 12 Temperature 12 UID 12 Factory reset 12 DMX protocols 13 O...

Page 3: ...Dimensions All dimensions are in millimeters WWW CLF LIGHTING COM 1 0 SPECTRUM P2 V W 106 260 290 Φ203 180 ...

Page 4: ...d observe all warnings in this manual and printed on the fixture If you have questions about how to operate the fixture safely please contact your supplier PROTECTION FROM ELECTRIC SHOCK l Disconnect the fixture from AC power before removing or installing any cover or part and when not in use l Always ground earth the fixture electrically l Use only a source of AC power that complies with local bu...

Page 5: ... onto any optical component besides the optional CLF Yara filters l Do not modify the fixture in any way not described in this manual l Do not use fixture on a dimmer PROTECTION FROM INJURY l Do not look continuously at LEDs from a distance of less than 3 meters from the front surface of the fixture without protective eyewear such as shade 4 5 welding goggles At less than this distance the LED emi...

Page 6: ...tachment point LCD Display 5P DMX input 5P DMX output AC mains power throughput AC mains power input G Clamp with Quicklock 875760 Optional Omega bracket with Quicklock 520114 Optional 3P DMX input optional CLF 13 453 3P DMX output optional CLF 13 454 P2 VARI WHITE SPECTRUM ...

Page 7: ...t breaker and ground fault earth fault protection Warning Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixtures can easily be disconnected from power Important Do not insert or remove live connectors to apply or cut power as this PowerCON TRUE 1 may cause arcing at the terminals that will damage t...

Page 8: ...ust be used to connect the first fixture to AC mains power connectors must be used to draw AC mains power from the fixtures power throughput PowerCON TRUE 1 sockets and yellow connectors must be used to supply power at the fixture s power input PowerCON TRUE 1 sockets No matter what the AC mains power voltage is do not connect more than ten the fixture in total including the first fixture to AC ma...

Page 9: ...face can support at least 10 times the weight of all fixtures and equipment to be installed on it Warning The supporting surface must be hard and flat or air vents in the base may be blocked which will cause overheating Fasten the fixture securely Do not stand it on a surface or leave it where it can be moved or can fall over Attach a securely anchored safety cable to the safety cable attachment p...

Page 10: ... one level in the menu structure press MODE Holding down the UP and DOWN button for more than 3 seconds the MENU display will rotate 180 Menu Manual Enter Test mode DMX address setting The DMX address also known as the start channel is the first channel used to receive instructions from the controller For independent control each fixture must be assigned its to a separate channel The DMX address c...

Page 11: ...WWW CLF LIGHTING COM 9 0 Control mode DMX control mode is selected in the CONTROL MODE menu The fixture has 5 DMX control modes 2ch 3ch 4ch 5ch 6ch Dimmer Cool white Warm white CCT Strobe Fade ...

Page 12: ...scroll through the options 2 CCT Easy color choice between 2800K warm white to 6000K cood white 3 Manual Color Mix your own color with each warm white and cool white value seperately Cool White Warm white CW WW Dimmer 000 255 Dimmer CW 000 255 Dimmer Cool white WW 000 255 Dimmer Warm white Strobe 00 20 Strobe 00 20Hz 2800 K 4500 K 3200 K 4800 K 3500 K 5000 K 3800 K 5500 K 4000 K 6000 K ...

Page 13: ...Auto program 2 3 Auto 3 Auto program 3 Here you can set all functions for the fixture personality Dimmer Speed Normal Smooth 1 Smooth 2 Smooth 3 Smooth 4 Dimmer curve linear Square law INV Square law S Curve Special KEY Lock Locks all the button functions Standard unlocking password is MODE UP MODE DOWN MODE UP MODE DOWN ENTER Refresh rate Controls the Flicker frequency of the fixture 600 1200 240...

Page 14: ...tensity control is coarser at low levels and finer at high levels l S CURVE light intensity control is finer at low levels and high levels and coarser at medium levels l Special the light intensity was linear increase with DMX value and light intensity control is finer at low level with DMX values decrease the dimmer speed will also has effect on it Whichever DIMMER CURVE option you select you can...

Page 15: ... 255 0 100 4 CCT 000 009 010 255 No function 6000K 2800K 5 Strobe 000 024 025 064 065 069 070 084 085 089 090 104 105 109 110 124 125 129 130 144 145 149 150 164 165 169 170 184 185 189 190 204 205 209 210 224 225 229 230 244 245 255 Shutter open Strobe 1 fast slow Shutter open Strobe 2 opening pulse fast slow Shutter open Strobe 3 closing pulse fast slow Shutter open Strobe 4 random strobe fast s...

Page 16: ...09 210 224 225 229 230 244 245 255 Shutter open Strobe 1 fast slow Shutter open Strobe 2 opening pulse fast slow Shutter open Strobe 3 closing pulse fast slow Shutter open Strobe 4 random strobe fast slow Shutter open Strobe 5 random opening pulse fast slow Shutter open Strobe 6 random closing pulse fast slow Shutter open Strobe 7 burst pulse fast slow Shutter open Strobe 8 random burst pulse fast...

Page 17: ...e law INV Square law S Curve Special Default linear Key Lock ON OFF Default OFF Refresh rate 600 1200 2400 4800 Default 4800 LCD brightness Level 1 10 DMX HOLD DMX HOLD NO DMX HOLD Default DMX HOLD 4 STATIC COLOR Fixed color CW WW CW WW Default CW WW CCT 2800K 3200K 3500K 3800K 4000K 4500K 4800K 5000K 5500K 6000K Default 4000K Manual color Dimmer 0 255 Default 255 CW 0 255 Default 255 WW 0 255 Def...

Page 18: ...r CLF 14 017 9 Power supply CLF 14 015 10 Power supply support bracket CLF 14 007 11 Case body CLF 14 001 12 Display board CLF 19 005 13 Display sticker CLF 19 004 14 Acrylic display support CLF 14 012 15 PowerCON TRUE1 input socket CLF 14 027 16 PowerCON TRUE1 output socket CLF 14 028 17 DMX 5 pin male chassis part waterproof CLF 14 032 18 DMX 5 pin female chassis part waterproof CLF 14 031 19 Va...

Page 19: ... materials 100 mm from fixture Minimum distance to illuminated surfaces 200 mm from fixture Connections AC power input PowerCON TRUE 1 input socket AC power throughput PowerCON TRUE 1 output socket DMX data in out 5 pin locking XLR 3 pin optional with CLF 13 453 CLF 13 454 Electrical AC power 100 240 V nominal 50 60 Hz Maximum total power consumption 110 W Power supply unit Auto ranging electronic...

Page 20: ...WWW CLF LIGHTING COM CLFLIGHTING SPECTRUM P2 VARI WHITE ...