background image

1942203 

V1.0  

19 June 2019 

 

Installation:

 

The  L10  Cleverfit  LED  Exit  can  be  installed  either  Ceiling  or  Wall  Mounted  and  can  be  mounted 
perpendicular to a wall using the (opti

onal) Cleverfit Cantilever Bracket. The fitting uses a “slide connect 

bracket base” that is mounted and wired into position first. The main body can be installed once the base 
is wired or later to avoid damage during the construction phase. Please follow the steps below to install 
the Cleverfit Exit: 

 

Disengage the slide connect bracket from the exit body. Position the base in the mounting position.  

 

Using the bracket as a guide, mark 2 holes for mounting and one for mains access. Then install the 
bracket using appropriate fixings (not supplied). 

 

Connect the 240VAC supply to the mounting bracket. 

 

Configure all the mounting parts and cable entry points as below (if required) and engage the body 
into the slide connect bracket. Apply mains power and check that the Cleverfit Exit is operational. 

 

If the CTP capabilities are activated, please affix the CTP status Label to a visible surface. 

 
Networking: 

When installing the product on a monitored network, (ZONEWORKS, DATA, DALI) simply insert the 
relevant Smart Node PCA. 

Dimensions: 

 

 
 
 
 
 
 
 

Testing:

 

Once connected to the 240V mains supply, the unit must be allowed to charge the battery for at least 24 
hours. Conduct the following tests: 
 

 

For the first test, the emergency lamp must remain illuminated for at least 2 hours after 
disconnection from the mains supply. 

 

Subsequent tests require the unit to illuminate for at least 90 minutes. The results of all tests are 
required to be recorded in a service logbook, which is to be kept on-site at all times. If the unit fails 
to remain illuminated for the requisite time, remedial action must be taken to repair the situation 
and once completed, the unit must pass a subsequent test. For more specific information, please 
refer to the current edition of the AS 2293.3 Standard. 

 

Cleverfit Maintenance: 

 

Lamp Replacement:

 

 

Use only the lamp(s) recommended on the 
label inside the Cleverfit.  

 

To replace the lamp bar, remove the self-
tapping screws, disconnect the signal cable 
and install the new lamp bar. 

 

Battery Replacement:

 

 

Use only the battery recommended on the 
label inside the Cleverfit and on this 
instruction. 

 

Remove the cable ties holding the battery, 
un-plug the lead from the PCB and remove 
the old battery.  

 

Clip the new battery into the holder, route 
the DC cable to the PCB and plug the new 
battery into the PCB.  

 

Secure the battery using suitable cable ties 

 

Trouble Shooting: 

Below are a list of common problems and their 
possible causes. 

 
Fault:  

The Green LED Test Switch 
indicator is not illuminated.

 

Check:   A.C. is connected and is turned on. 
 

Battery is connected 
Test Switch for damage. 
 

Fault:  

Lamp does not illuminate in 
emergency mode. 

 

Check:   A.C. is connected. 
 

Lamp is correctly inserted. 

 

Battery is connected 

 

Fault:  

Lamp illuminates in emergency 
mode, but only stays on for a short 
period. 

Check: 

Battery has been allowed to charge for 
at least 24 hours. 

 

Battery for damage.

 

 

Rated Emergency Lumen Output in accordance with AS2293.1 (refer 
to spacing tables for installation positions):

 

 

 

Refer to the Technical Label for classification information. 
 

Caution:

 

On many building sites, power circuits may be cut off in an uncontrolled and repetitive basis during 
construction. As a result, any Exit & Emergency Units, on these circuits, will have their batteries 
discharged or “cycled”. The battery in this fitting has been selected to give excellent long-life 
performance in a controlled AS2293 testing environment. Excessive battery cycling will reduce through-
life performance and may lead to premature battery failure. Battery warranty claims, as a result of such 
abuse, are specifically EXCLUDED from Clevertronics warranty terms. 
 

Warranty:

 

For Product Warranty information and Terms and Conditions of Sales please refer to our website 

http://clevertronics.com.au/terms-conditions-sale-australia-nz/

 

 

 

 

 