background image

1942488 

V1.0  

2nd August 2021 

Instruction Sheet Template - V1.1 

 Updated 23/11/2020 

Installation:

 

The Argonaut Square can be installed either Ceiling or Wall Mounted.  

 

Remove the four (4) screws holding the diffuser to the base. 

 

Remove the four (4) screws holding the gear tray to the base. 

 

Determine  the  cable  access  point.  There  are  2  locations  on  opposite  sides  of  the  fitting  for  cable 
gland/conduit entry. Entry can also be from the back of the base. Drill out the desired cable entry 
point. 

Note: Only round cables are to be used with the cable gland for an IP65 seal. Keep cable 
entry straight and tension free.  Ensure all seals are tight.  
min. wire diameter 7mm, max. 12mm. 

 

Drill out 4 of the mounting points in the base (see image below). 

 

Using the base as a guide, mark the 4 holes for mounting and one for mains access if using back 
cable entry.  

 

Mount  the  base  using  appropriate  fixings  and  seal  these  fixings  with  appropriate  sealant  (fill  any 
additional entry points with same sealant also).

 

 

Route the power inside the base. 

 

Connect the 240VAC (L,E,N) supply to the terminal block of the gear tray. 

 

Install the gear tray to the base. 

 

Apply power to the fitting and test per the instructions. 

 

 

NOTE: 

This luminaire (with reinforced insulation between control/LED terminal and AC Supply) contains non-

user replaceable light source 

– to be replaced (if required) by the manufacturer or his service agent or a 

similar qualified person. 

 

Dimensions:  

 

Driver Setting:

 

For non -SEN / -DD products 

 

 

 

 
Trouble Shooting: 

Below are a list of common problems and their possible causes. 

 

Fault:  

The LED Strip is not illuminated.

 

Check:   A.C. is connected and is turned on. 
 

Wiring connections between the LED Driver & LED Strips 

 

 

 

Reviews: