Clever RADSON MILO H + V Manual Download Page 4

4

InstAllAtIon

Mark out the distance between the brackets as shown in the table and 
in the drawings below. Next mark the holes to be drilled and secure the 
supports using a suitable fastening for the type of wall. Refit the spring 
locking  device  in  its  upper  fixed  position,  locate  the  brackets  on  the 
notches, and then press the top of the radiator towards the wall until 
the fixing system engages on the brackets.
The thermostat housing must always be at the bottom, as close as pos-
sible to the floor. The distance between the wall and the radiator is 50 
mm, regardless of the model.

A1 + A2

(1)   Effective  Power:  The  radiator  is  equipped  with  an  electronic  tem 
 

perature guard that will prevent the surface temperature to reach  

 

excessive values. In such case, the heating element of the radiator  

 

will only be enabled to function during 65% of the full heating cycle,  

 

and as such limiting the heat output to 65% of the nominal power.  

 

This value corresponds to the effective power.

(2)   Average power.

A1

*   Three fixing systems.
**   The support for this model is positioned asymmetrically in order to  
 

leave room for the thermostat.

A2

The vertical radiators (H =>1500) are supplied with safety chains, which 
are fitted between the radiator fixing elements and the wall brackets. 
Radiators with a height of 1500 mm or above are provided with fasten-
ings at the centre. For hooking and mounting, lift up all the fixing ele-
ments into the mounting position (use the hook supplied to facilitate 
this operation), and then push the radiator against the fastenings until 
the spring lock emits a click. Check that all the fastenings are securely 
locked.

B

Towel  rails  (HDH  400)  are  available  as  an  option  for  vertical  radiators 
with a width of 400 mm. The HDH 400 consists of two fixed bars. The 
distance between the upper bar and the lower bar is 27 cm. The distance 
“h” is proposed to be about 10 cm.

ConneCtIon dIAgrAm

Refer  to  the  wiring  diagram  when  connecting  the  radiator. The  radia-
tor is prepared for a reduction in temperature of 4°C from the built-in 
switch or from an external programmer. It is essential to adhere to the 
phase and neutral polarities.

Radiator

Brown
Blue

Black

Pilot wire

All electric radiators are class II   , and are protected against
water  ingress  in  accordance  with  IP32.  They  must  not  therefore  be 
earthed. They must be installed only in volume 3 (fig D and E) in bath-
rooms and in other indoor areas. This appliance is equipped with an all-
pole switch with a contact separation of at least 3 mm.

mAIntenAnCe

Use an ordinary liquid cleaner (e.g. washing-up liquid). Do not use abra-
sive  products,  which  could  damage  the  surface  of  the  radiator.  Stains 
(oil, etc.) may be removed easily with a solvent such as acetone. Surface 
scratches may be removed by polishing the surface with fine abrasive 
paper.

WhAt Is A mInerAl ComposIte?

It is a material composed of ground minerals embedded in a binder.

ho W to oper Ate YoUr ApplI AnCe

The radiator is turned on by moving the switch, marked I and O, to the 
ON position I.

settIng the desIred temperAtUre

•   Position the knob (fig. 4) to CONF (Comfort).
•   Place a thermometer in the room concerned, at a sufficient distance  
 

from the radiator (on a piece of furniture, for example).

•   Move  the  thermostat  knob  (fig.  2)  close  to  setting  4  (the  light  is   
 

illuminated) in fig. 3.

•   Watch your thermometer until the desired temperature is reached
 

(for  example  19°C).  Once  this  temperature  is  achieved,  turn  the   

 

thermostat knob gently to the left until the light goes out, and no  

 

further.

•   Your temperature is then set.

When the thermostat knob is set to *, your appliance will then assure 
the protection of your room against frost (about 7°C).

InstAllAtIon WIthoUt A progrAm Control UnIt

In this case, you must not use the pilot wire (black wire). Isolate it inside 
the junction box.
The environment knob (fig. 4) must be set to CONF (Comfort).
If you set this knob to Eco, you will obtain between 3 and 4°C less in the 
room. For example, if you had set your thermostat to 19°C, you would 
obtain 15 or 16°C.
This may be interesting if you wish to maintain a reduced temperature 
in a room that is generally unoccupied without disturbing your thermo-
stat. To return to your comfort temperature, it is sufficient to reposition 
the knob to CONF.

InstAllAtIon WIth A progrAm Control UnIt

Our  appliances  are  equipped  with  a  supplementary  wire  (black  wire) 
known as the ”pilot wire”. This permits your appliance to receive elec-
trical commands from a program control unit. (Ask your electrician for 
advice.)
Your radiator is designed to interpret 6 different commands:
1-   Comfort - The temperature that you have set on your thermostat
 

(for example 19°C).

2-   Frost-free – Fixed temperature of about 7°C.
3-   Stop – The appliance is on stand-by but is not heating.
4-   Low-level operation – Between 0 and 15° lower, as preferred.
5-   Low-level operation – 2°C lower
6-   Low-level operation – 1°C lower
Turn the knob (fig. 4) to PROG (programme) and continue to rotate it to 
the right to select the value of the automatic reduction in temperature 
(0-15°C). For example 4°C lower at night.

prIorItY fUnCtIons on the progrAm Control UnIt

You require one or more of the radiators to remain in comfort mode. Set 
the knob (fig. 4) to CONF*. You require one or more of the radiators to 
remain in low-level operation mode. Set the knob (fig. 4) to ECO*
*   Commands received by the program control unit are ignored by the  
 

radiator in this case.

loW And verY loW temperAtUre fUnCtIons (fIg. 5)

Selecting one or other of these functions in no way changes either the 
output of your appliance or the temperature that you have set for your 
room.

low temperature (n)

The surface temperature of the appliance does not exceed 60°C in nor-
mal operation.

very low temperature* (l)

The surface temperature of the appliance does not exceed 45°C in nor-
mal operation.
*Recommended, for example, for the bedroom of a small child, day nurs-
eries, nursery schools, etc.

mIsCellAneoUs

WArnIng - In order to avoid overheating, do not cover the 
heater.

“Do not cover” means that the radiator must not be used for 
drying clothes, for example, by placing them directly on the 
radiator.

The radiator is equipped with a over heat protection device which cuts 
the current if the radiator is overheated. It is not possible to reset this 
component which means that the whole radiator must be replaced in 
such a case.
If the supply cord is damaged, it must be replaced by the manufacturer, 
its service agent or similarly qualified persons in order to avoid a hazard.
WARNING: The heater must not be used if the panel is damaged.
This  appliance  is  not  intended  for  use  by  persons  (including  children) 
with reduced physical, sensory or mental capabilities, or lack of experi-
ence and knowledge, unless they have been given supervision or instruc-
tion concerning use of the appliance by a person responsible for their 
safety.  Children  should  be  supervised  to  ensure  that  they  do  not  play 
with the appliance.

Warranty

The warranty is valid for 10 years except for electrical components which
is valid for 2 years. In the event of any problems or repairs, please contact 
your supplier.

nB: the rAdIAtor mUst Be InstAlled BY An AUthorIsed  
eleCtrICIAn onlY

The radiator must not be mounted below an electrical socket outlet. 
If the radiator is installed in a bathroom or shower room, it must be 
installed so that it is not possible to reach the switch or thermostat 
from the bath or shower.

 

INSTRUCTIONS 
FOR FITTING AND USE

Summary of Contents for RADSON MILO H + V

Page 1: ...electronic thermostat Radiateur lectrique en r sine granit e avec thermostat lectronique Elektrische radiator in gegoten graniet met elektronische thermostaat Elektroheizk rper aus Gussgranit mit elek...

Page 2: ...r 1 Puissance effective Effectieve afgifte Effektive Leistung W 2 H mm L mm A mm B mm C mm D mm 400 260 600 400 215 110 150 370 600 390 600 600 215 205 145 370 800 520 600 800 215 410 145 370 1000 650...

Page 3: ...ieve afgifte Effektive Leistung W 2 L mm H mm A mm B mm C mm D mm M mm 600 390 400 900 95 220 365 370 1000 650 400 1500 90 220 350 987 435 1200 780 400 1800 95 215 375 987 435 1500 975 600 1500 110 38...

Page 4: ...ection of your room against frost about 7 C Installation without a program control unit In this case you must not use the pilot wire black wire Isolate it inside the junction box The environment knob...

Page 5: ...ort Si vous positionnez ce bouton sur Eco vous obtiendrez entre 3 et 4 C de moins dans la pi ce Par exemple si vous aviez r gl votre thermostat 19 C vous obtiendriez 15 ou 16 C Cela peut tre int ressa...

Page 6: ...iet verder Uw temperatuur is nu ingesteld Als u de thermostaatknop op instelt schakelt het toestel over op een vorstvrije stand ong 7 C Installatie zonder programmaregelaar In dit geval moet u de rege...

Page 7: ...Raum vor Frost ungef hr 7 C Montage ohne Programmregeleinheit In diesem Fall d rfen Sie die Steuerleitung schwarzer Draht nicht verwen den Isolieren Sie die Leitung im Inneren der Verteilerdose ab De...

Page 8: ...torit s de votre commune ou le service de collectes des d chets ou encore le magasin o vous avez achet l quipement Ceci s applique aux pays dans lesquels ladite directive est entr e en vigueur VERWERK...

Reviews: