When the ignition module reads 1.0 micro amps DC current through the 

ground wire the coil to the main gas valve is energized 

 

The pilot flame lights the main burner. 

 

If the module does not read 1.0 micro amps DC in 90 seconds it will shut 

down the main burner and make one more try before locking out. 

 

5.

 

The water in the boiler is heated to steam.  

 

As steam is generated and pressure builds the air is pushed out through the steamtrap 

on the lower steam manifold. 

 

Steam goes through the steam trap heating it to 192 degrees closing the steam trap. 

6.

 

Pressure builds in the boiler to the set point of 8-10 PSI. 

 

The operating pressure switch opens and the heat circuit is de-energized. 

7.

 

With the timed/manual switch in the timed position and time on the timer. 

 

115 VAC is sent to the steam solenoid and steam is sent to the cooking cabinet.  There 

the steam is directed around the product. 

 

115 VAC is sent to the “Pause” or “Sure Cook” light. 

 

115 VAC is sent to the normally open contacts of the compartment thermostat. 

 

The  normally  open  contacts  of  the  compartment  thermostat  close  when  the 

compartment temperature reaches 193 degrees 

 

115 VAC is sent to the timer motor and the timer begins to count down. 

 

115 VAC is sent to the condensate solenoid and cold water is sent to the condensate 

spray nozzle pulling the steam down the drain. 

 

When  the  steam  pressure  drops  below  the  operating  set  point  the  heat  circuit  is 

energized and the heat process begins again. 

  

8.

 

Water continues to fill the boiler until the operational water float is lifted and closes, shorting 

the HI terminal on the water level board to the C terminal. . 

 

When the HI terminal is shorted to the C terminal the WF terminal on the water level 

board is de-energized. 

 

If  the  water  level  drops  below  the  operational  water  float  switch  for  more  than  5 

seconds the WF terminal is energized and the water fill circuit begins again. 

 

9.

 

When the mechanical timer counts down: 

 

115 VAC is removed from the condensate circuit. 

 

115 VAC is removed from the steam solenoid. 

 

115 VAC is sent to the 3-second timer 

 

115 VAC is sent from the 3-second timer to the buzzer for 3 seconds. 

 

10.

 

With the timed/manual switch in the Manual position 

 

115 VAC is sent to the steam solenoid and steam is sent to the cooking cabinet.  There 

the steam is directed around the product. 

 

115 VAC is sent to the “Pause” or “Sure Cook” light. 

 

115 VAC is sent to the normally open contacts of the compartment thermostat. 

 

The  normally  open  contacts  of  the  compartment  thermostat  close  when  the 

compartment temperature reaches 193 degrees 

Summary of Contents for SteamCraft Power 10

Page 1: ...technical and technological changes revisions or updates Cleveland Range LLC assumes no liability or responsibility regarding errata changes revisions or updates Qualified Cleveland Range LLC Authoriz...

Page 2: ...Cleveland Range LLC 1333 East 179th St Cleveland Ohio U S A 44110 Ph 1 216 481 4900 Fx 1 216 481 3782 Visit our Web Site at www clevelandrange com...

Page 3: ...ounded for 20 seconds 115 VAC is removed from HTR and sent back to IND energizing the low water light 3 When the momentary amber switch is depressed 115 VAC is sent to the R1 relay closing it The norm...

Page 4: ...mer begins to count down 115 VAC is sent to the condensate solenoid and cold water is sent to the condensate spray nozzle pulling the steam down the drain When the steam pressure drops below the opera...

Page 5: ...ized and the heat process begins again 11 The unit is turned off by depressing the red rocker switch 115 VAC is removed from the timing and heat circuits 115 VAC is removed from the normally open blow...

Page 6: ......

Page 7: ......

Page 8: ...closed R1 contacts to energize the amber light If the low water cut off probe is not grounded for 20 seconds 115 VAC is removed from HTR and sent back to IND energizing the low water light 3 When the...

Page 9: ...cted around the product and pulled down the drain by the condensate spray When the cooking compartment reaches 193 degrees internally the thermal switch closes and the timer begins to count down 115 V...

Page 10: ...ing the steam down the drain 11 The unit is turned off by depressing the red rocker switch 115 VAC is removed from the timing and heat circuits 115 VAC is removed from the normally open blowdown valve...

Page 11: ......

Page 12: ......

Page 13: ...es the Amber light go off With the High Limit pressure switch temporarily bypassed does the Amber light go off when the reset switch is depressed No Yes No Replace the high limit pressure switch Repla...

Page 14: ...solenoid Replace the fill solenoid Yes Is water leaving the fill solenoid Replace wiring to drain solenoid Does the steamer have the optional intermittent blowdown timer Replace the wiring to the int...

Page 15: ...terminal is there 1 0 micro amp DC to the ignition module No Is there flame at the pilot assy Yes Yes No Replace pilot assy and ignition wire Yes Yes Replace the pilot assy and ignition wire No Boile...

Page 16: ...t See Boiler won t ignite Yes Is the low water indicator on 120 VAC bewtween the IND and L2 terminals on the waterboard Clean or replace the low water probe Is high pressure switch opening prematurely...

Page 17: ...eam leaks around the door Steam Leaks Around Door Is COLD water supplied to the steamer Supply cold water 35 60 PSI to the steamer No Is the door gasket physically damaged Yes Turn over the gasket or...

Page 18: ...1333 East 179th Street Cleveland Ohio 44110 Phone 216 481 4900 Fax 216 481 3782...

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ......

Reviews: