Cleveland SteamCraft Power 10 Manual Download Page 14

Boiler won't fill.

Yes

No

No

Yes

No

Yes

Yes

No

No

Yes

No

No

Yes

No

No

Yes

Yes

Yes

No

PROBLEM:

24CGP10

Gas boiler

won't fill

Yes

Is there 115 VAC

to the steamer?

Is there water to

the steamer?

Supply 115

VAC to the

steamer.

Supply cold
water to the

steamer.

Replace the

on/off rocker

switch .

Is there 120 VAC

between the L1

and L2 on the

water board?

Is there

 120 VAC between

L2 and W F on the

water board?

Replace the

wiring to the fill

solenoid.

Is there

120 VAC across
the coil of the fill

solenoid?

Replace the fill

solenoid

Yes

Is

 water leaving the

fill solenoid?

Replace wiring

to drain

solenoid.

Does

 the steamer have

the optional

intermittent

blowdown timer?

Replace the
wiring to the

intermittent

blowdown

timer .

Is

there 120 VAC

between terminals

2&3 on the timer?

Replace the

intermittent

blowdown

timer.

Is there

 120 VAC across

the coil of the

drain valve?

Is water draining

from the

generator?

If water

 is leaving the fill
solenoid and not

draining from the

generator where is it

going? check  for

leaks..

Remove

 the wire from the HI

terminal on the water

board. Is there 120

VAC between L2 and

WF?

Replace the
water board

Replace the

drain valve.

No

Replace float

switch

Yes

Summary of Contents for SteamCraft Power 10

Page 1: ...technical and technological changes revisions or updates Cleveland Range LLC assumes no liability or responsibility regarding errata changes revisions or updates Qualified Cleveland Range LLC Authoriz...

Page 2: ...Cleveland Range LLC 1333 East 179th St Cleveland Ohio U S A 44110 Ph 1 216 481 4900 Fx 1 216 481 3782 Visit our Web Site at www clevelandrange com...

Page 3: ...ounded for 20 seconds 115 VAC is removed from HTR and sent back to IND energizing the low water light 3 When the momentary amber switch is depressed 115 VAC is sent to the R1 relay closing it The norm...

Page 4: ...mer begins to count down 115 VAC is sent to the condensate solenoid and cold water is sent to the condensate spray nozzle pulling the steam down the drain When the steam pressure drops below the opera...

Page 5: ...ized and the heat process begins again 11 The unit is turned off by depressing the red rocker switch 115 VAC is removed from the timing and heat circuits 115 VAC is removed from the normally open blow...

Page 6: ......

Page 7: ......

Page 8: ...closed R1 contacts to energize the amber light If the low water cut off probe is not grounded for 20 seconds 115 VAC is removed from HTR and sent back to IND energizing the low water light 3 When the...

Page 9: ...cted around the product and pulled down the drain by the condensate spray When the cooking compartment reaches 193 degrees internally the thermal switch closes and the timer begins to count down 115 V...

Page 10: ...ing the steam down the drain 11 The unit is turned off by depressing the red rocker switch 115 VAC is removed from the timing and heat circuits 115 VAC is removed from the normally open blowdown valve...

Page 11: ......

Page 12: ......

Page 13: ...es the Amber light go off With the High Limit pressure switch temporarily bypassed does the Amber light go off when the reset switch is depressed No Yes No Replace the high limit pressure switch Repla...

Page 14: ...solenoid Replace the fill solenoid Yes Is water leaving the fill solenoid Replace wiring to drain solenoid Does the steamer have the optional intermittent blowdown timer Replace the wiring to the int...

Page 15: ...terminal is there 1 0 micro amp DC to the ignition module No Is there flame at the pilot assy Yes Yes No Replace pilot assy and ignition wire Yes Yes Replace the pilot assy and ignition wire No Boile...

Page 16: ...t See Boiler won t ignite Yes Is the low water indicator on 120 VAC bewtween the IND and L2 terminals on the waterboard Clean or replace the low water probe Is high pressure switch opening prematurely...

Page 17: ...eam leaks around the door Steam Leaks Around Door Is COLD water supplied to the steamer Supply cold water 35 60 PSI to the steamer No Is the door gasket physically damaged Yes Turn over the gasket or...

Page 18: ...1333 East 179th Street Cleveland Ohio 44110 Phone 216 481 4900 Fax 216 481 3782...

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ......

Reviews: