Cleveland SteamCraft Power 10 Manual Download Page 15

Is there 24 VAC to

the ignition

module?

Is there spark to

the igniter and 24

VAC to the pilot

coil of the gas

valve for 90

seconds?

Yes

Is there gas to the

pilot assy?

Is there at least

1.0 micro amp DC

to the burner

ground terminal at

the ignition

module?

Replace the

ignition module

See 

Boiler

won't build

pressure

.

No

Replace the

ignition module

No

Is there gas to the

unit?

No

Supply gas to

the Steamer.

No

Replace the

gas valve.

After replacing the

ground wire to the

burner ground

terminal , is there

1.0 micro amp DC

to the ignition

module?

No

Is there flame at

the pilot assy?

Yes

Yes

No

Replace pilot

assy and ignition

wire

Yes

Yes

Replace the

pilot assy and

ignition wire

No

Boiler won't heat.

start

PROBLEM

:

24CGP10

Gas boiler

won't ignite

PROBLEM:  24CGP10 Gas Boiler Overfills

Boiler over fills

With water in the

sight glass is there

120 VAC between

terminals L2 and
WF on the water

board.?

Replace the fill

solenoid

With a jumper

across terminals

HI and C on the

waterboard,  is
there 120 VAC

between L2 and

WF?

Yes

Replace ;the

water board

Yes

Replace the float

switch.

No

No

Yes

Is there 24 VAC to
the main valve coil

on gas valve?

Yes

No

Replace the

gas valve

Yes

Summary of Contents for SteamCraft Power 10

Page 1: ...technical and technological changes revisions or updates Cleveland Range LLC assumes no liability or responsibility regarding errata changes revisions or updates Qualified Cleveland Range LLC Authoriz...

Page 2: ...Cleveland Range LLC 1333 East 179th St Cleveland Ohio U S A 44110 Ph 1 216 481 4900 Fx 1 216 481 3782 Visit our Web Site at www clevelandrange com...

Page 3: ...ounded for 20 seconds 115 VAC is removed from HTR and sent back to IND energizing the low water light 3 When the momentary amber switch is depressed 115 VAC is sent to the R1 relay closing it The norm...

Page 4: ...mer begins to count down 115 VAC is sent to the condensate solenoid and cold water is sent to the condensate spray nozzle pulling the steam down the drain When the steam pressure drops below the opera...

Page 5: ...ized and the heat process begins again 11 The unit is turned off by depressing the red rocker switch 115 VAC is removed from the timing and heat circuits 115 VAC is removed from the normally open blow...

Page 6: ......

Page 7: ......

Page 8: ...closed R1 contacts to energize the amber light If the low water cut off probe is not grounded for 20 seconds 115 VAC is removed from HTR and sent back to IND energizing the low water light 3 When the...

Page 9: ...cted around the product and pulled down the drain by the condensate spray When the cooking compartment reaches 193 degrees internally the thermal switch closes and the timer begins to count down 115 V...

Page 10: ...ing the steam down the drain 11 The unit is turned off by depressing the red rocker switch 115 VAC is removed from the timing and heat circuits 115 VAC is removed from the normally open blowdown valve...

Page 11: ......

Page 12: ......

Page 13: ...es the Amber light go off With the High Limit pressure switch temporarily bypassed does the Amber light go off when the reset switch is depressed No Yes No Replace the high limit pressure switch Repla...

Page 14: ...solenoid Replace the fill solenoid Yes Is water leaving the fill solenoid Replace wiring to drain solenoid Does the steamer have the optional intermittent blowdown timer Replace the wiring to the int...

Page 15: ...terminal is there 1 0 micro amp DC to the ignition module No Is there flame at the pilot assy Yes Yes No Replace pilot assy and ignition wire Yes Yes Replace the pilot assy and ignition wire No Boile...

Page 16: ...t See Boiler won t ignite Yes Is the low water indicator on 120 VAC bewtween the IND and L2 terminals on the waterboard Clean or replace the low water probe Is high pressure switch opening prematurely...

Page 17: ...eam leaks around the door Steam Leaks Around Door Is COLD water supplied to the steamer Supply cold water 35 60 PSI to the steamer No Is the door gasket physically damaged Yes Turn over the gasket or...

Page 18: ...1333 East 179th Street Cleveland Ohio 44110 Phone 216 481 4900 Fax 216 481 3782...

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ......

Reviews: