19
CAUTION
Do not use any other product or method of descaling other than the
DISSOLVE
®
Descaler method using Part No. 106174.
Failure to do so can cause injury and equipment damage.
•
Cleveland Range recommends DISSOLVE® Descaler Solution, Part No. 106174.
•
Use no other system of steamer descaling
•
Appropriate warnings and safe handling procedures must be provided to handlers and users
•
Instructions and warnings on Dissolve® containers and Material Safety Data Sheets
supercede and replace instructions and warnings in this manual
•
General precautions: wear rubber gloves, splash goggles and other protective clothing and
equipment as necessary. Refer to Dissolve® container labels and Material Safety Data
Sheets for information regarding eyewash, first aid, medical treatment, and spill control.
MODEL 22CGT3 and 22CGT6, BOILERLESS STEAMER DESCALING PROCEDURE for DISSOLVE
®
Descaler Solution Part No. 106174.
•
The entire procedure must be read and fully understood before beginning descaling.
•
This procedure takes about 1 hour 30 minutes to complete.
•
Repeat this procedure as needed for heavy scale buildup.
•
Regular cleaning of the steamer with vinegar per the instructions found in Chapter 6 may help
reduce need for descaling.
•
Sides, back, and top of steam compartments may be descaled with a vinegar solution and a soft
brush. See Chapter 6.
1) Open the door to the cooking compartment.
2) Set the TIMED/MANUAL switch to TIMED
OR
the ON/OFF switch to OFF.
3) Set the ON/OFF lever to the OFF position.
•
The 3-minute drain rinse cycle starts.
4) Remove the Pan Racks and KleanShield
™
from inside the steamer.
•
Heavily scaled pan racks and KleenShield™ may be descaled by soaking them in a solution
of 1 part Dissolve® and 4 parts water, rinsing thoroughly with cold water, and washing them in
a dishwasher.
5) Remove any loose scale from the bottom of the steamer.
6) When the drain cycle is done
,
turn the ON/OFF lever to ON to refill the unit.
7) Do not start the timer.
8) Leave the door open.
NOTE: DO NOT HEAT THE STEAMER DURING DESCALING.
WARNING
Descaling procedure is slightly different depending on model.
This entire procedure must be read and fully understood as it
applies to the model being descaled, before beginning
descaling operations.
Failure to do so can cause injury and equipment damage.