background image

Cleveland

Project  ________________________________

Item  __________________________________

Quantity  _______________________________  

FCSI Section  ____________________________

Approval  _______________________________

Date  __________________________________

1333 East 179 St.,

Cleveland, Ohio, U.S.A. 44110 

Tel: 1-216-481-4900

Fax: 1-216-481-3782

Web Site: www.ClevelandRange.com

Email: [email protected]  

 

PRESSURE STEAMERS

Cleveland Standard Features

I

I

5 psi Operating Pressure in cooking compartments

I

I

Mechanical interlock prevents unlatching door while compartment

is pressurized

I

I

Timers, one per compartment, are mechanical style with 

audible signal

I

I

Thermostatic Trap vents cooking compartment automatically

I

I

Steam Inlet Valves and Exhaust Valves interlocked for 

synchronous action

I

I

8 psi Compartment Safety Valve

I

I

Capacity per compartment for eight, 12” x 20” x 2 1/2” deep

Cafeteria Pans, or four, 18” x 26” Bun Pans

I

I

Heavy Duty, free floating, cast aluminum compartment doors

I

I

Compartment Door Hinges have adjustable hinge pins and

self-lubricating bushings

I

I

Door Gasket replaceable without tools

I

I

Pressure Gauge for compartment Operating Pressure

I

I

Compartment Slide Racks are removable without tools, for

easy cleaning

I

I

Type 430 Stainless Steel: external enclosure, Table Top and

eight gauge plate cooking compartments

I

I

Modular Cabinet Base with Hinged Doors

I

I

High efficiency Gas-Fired Steam Generator with NickelGard

and Automatic Water Fill on start-up

I

I

Automatic Water Level Control System with Low Water Power

Cut-off Circuit

I

I

Steam Generator equipped with High-limit Pressure Safety

Switch and Safety Valve

I

I

Automatic Steam Generator (boiler) Blowdown allows intermittent

control, complete with additional Manual Drain Valve

I

I

Steam Generator with Electronic Spark Ignition

I

I

Single Cold Water Connection (no hot water required)

I

I

6” Stainless Steel Legs with level adjustment and flanged feet

I

I

Gas Pressure Regulator and Control Valve

I

I

Standard Voltage 115 volts, 60 hz, single phase

I

I

All Major Components are serviceable from the front of unit

Options & Accessories

Ë

Automatic Steam Inlet and Exhaust Operation (AT-2):

includes 60 minute Automatic Timers and Manual Bypass

Ë

15 psi for Kettle Operation, includes Power Take-Off (PTO)

Ë

Kettle Interconnecting Kit (IMK)

Ë

Stainless Steel Insulated Flue (SSF)

Shall  be  _____ Compartments,  CLEVELAND,  Pressure  Steamer,

Model PGM- _____ - _____ , Gas-fired Steam Generator, _____ M BTU

input;  _____ volts,  single  phase.  Each  Cooking  Compartment

equipped with: 60 Minute Timer; Pressure Safety Valve; Heavy-duty,

free  floating  Door  with  Safety  Interlock;  and  synchronous  operating

Steam  Inlet  and  Exhaust/Drain  Valves.  Solid  State  Controls  operate

Water  Level  and  Steam  Generator  (boiler)  Safety  Functions.

Automatic  Steam  Generator  (boiler)  Blowdown  with  additional

Manual Drain Valve. 

Ë

Special Compartment Slide Racks

Ë

Stainless Steel base Frame (FSS)

Ë

12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep

Ë

Intermediate Pull-Out Shelf (POS)

Ë

Spray Head with flexible Hose (SH)

Ë

Gas Option, other than natural 

Ë

Secondary Low Water Cut-Off, factory installed (CALG)

(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT.

NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)

Ë

Water Filters

Ë

Rear Gas Connection (RGT)

Ë

Correctional Packages

Short Form Specifications

PRESSURE STEAMERS

2 OR 3 COMPARTMENTS, GAS FIRED STEAM GENERATOR
200 OR 300M BTU, 36” WIDE CABINET BASE
with NICKELGUARD™

MODELS

:

2 Compartments

3 Compartments

PGM-200-2

PGM-200-3

PGM-300-2

PGM-300-3

1

0

0

%

5

Ye

ar Boiler

W

a

rr

a

n

ty

N

ic

ke

lGuar

d

SECT.

VI

PAGE 

 3

1007

Reviews: