background image

Right - 6”, Left - 6”, Rear - 6” 

(12” on control side if adjoining 

wall or equipment is over 30” 

high for service access)

For use in non-

combustible locations.

Contact factory for 

variances to clearances.

The Floor Drain must be

located outside the con-

fines of the equipment.

1 1/2” IPS common drain.
Do not connect other units

to this drain.
Do not use PVC pipe for

drain.

(NOT TO SCALE)

SECT.

VI

PAGE 

4

1007

Litho in U.S.A.

Each compartment has capacity for:

Eight, 12˝ x 20˝ x 2

1

2

˝

Cafeteria Pans or

Six,

12˝ x 20˝ x 4˝

Cafeteria Pans or

Four, 12˝ x 20˝ x 6˝

Cafeteria Pans or

Four, 18˝ x 26˝

Bun Pans

Many regional, state and local codes exist and it is

the   responsibility of the owner and installer to com-

ply with those codes.

Cleveland Range equipment is built to comply with

applicable standards for manufacturers. Included

among those approval agencies are: ASME/N.Bd.,

NSF, CSA (AGA, CGA).

WATER QUALITY REQUIREMENT

The recommended minimum water quality standards

whether untreated or pre-treated, based upon 10 hours

of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million

TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on site

water analysis for recommendations concerning steam

generator feed water treatment (if required), in order to

remove or reduce harmful concentrations of minerals.

The use of highly mineralized water will mean that more

frequent  servicing  of  the  steam  generator  will  be 

necessary. The fact that a water supply is potable is not

proof that it will be suitable for the generator.

NOTES

:

**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM.

Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, NSF and CSA (AGA, CGA).

5.0 Amps
** Do not connect to GFI

outlet. See note below.

Reviews: