ELECTRICAL CONNECTION
Fused disconnect
A separate fused disconnect (supplied by installer) is required for this equipment. Follow chart
below to properly size disconnect.
Model
Supply
voltage
Amps
Phase
Wire Size mm2
Fused
Disconnect
AMPS
MKDL-40-T to MKDL-150-T
200-208 15
3
3.3
20
TMKDL-40-T to TMKDL-150-T
220-240 14
3
3.3
20
380-415 9
3
2.1
15
ELECTRICAL
NOTE
: Ensure the electrical supply matches the unit’s requirements as stated on the rating label.
This unit is built to comply with CE standards. Many local codes exist, and it is the responsibility
of the owner and installer to comply with these codes.
NOTE
: Maximum voltage for LVD is 440 volts for CE marked appliances.
ELECTRICAL SERVICE CONNECTIONS
The electric supply must match the power requirements specified on the kettle's rating plate. The
copper wiring must be adequate to carry the required current at the rated voltage. Refer to the
specification sheet for electrical specifications.
1. Ensure main power is turned off before connecting wires.
2. Remove the screws at the rear of the center console cover, and remove the cover. A wiring
diagram is affixed to the underside of the console cover.
3. Feed permanent copper wiring 18" through the cut-out in the bottom of the console. Connect
wiring in junction box in the bottom of the console.
4. Turn main power back on.
5. Check for correct rotation of electric motor (access by removing top front cover on center
console). If rotation is incorrect, disconnect main power and reverse any two of the three live
lines.
6. Replace the console cover and secure it with screws.
RED
YELLOW
BLACK
BLACK
BLUE
RED
L1 L2 L3
3
RED
YELLOW
BLACK
BLACK
BLUE
RED
L1
L2
1
Green/
Yellow
PE
Green/
Yellow
PE
The kettle is wired for 3-phase operation at the factory.
United Kingdom