FOR YOUR

 

SAFETY

 

DO NOT STORE OR USE GASOLINE OR 
OTHER FLAMMABLE LIQUIDS AND 
VAPOURS IN THE VICINITY OF THIS OR 
ANY OTHER APPLIANCE.

 

 
 
 
 
 
 
 
 
 
 

GENERAL INSTALLATION INSTRUCTIONS 

Installation  of  kettle  must  be accomplished 
by qualified installation personnel, working to 
all applicable local and national codes. 
Improper installation of product could cause 
injury or damage. 

This equipment is built to comply with 
applicable standards for manufacturers. 
Included among those approval agencies are:  
UL, A.G.A, NSF. ASME/N.Bg, CSA, CGA, ETL, 
and others. Many local codes exist, and it is 
the responsibility of the owner and installer to 
comply with these codes.  

Observe all clearance requirements to provide 
proper make-up air flow as well as sufficient   
clearance  for  servicing. Dimensions and 
clearance specifications are shown on the 
specification sheet. Do not install kickplates or 
otherwise obstruct the flow of combustion and 
ventilation air. Check the rating plate to ensure 
that the kettle has been equipped to operate 
with the type of gas available at the installation. 

Gas fired kettles are only to be installed under 
a ventilation hood in a room which has 
provisions for adequate make up air. 

Electrical  installation  must  be  in accordance 
with local codes and/or the National Electric 
Code ANSI/NFPA 70-1987 (USA) or the 
Canadian Electrical Code CSA Standard C22.1 
(Canada). The kettle must be electrically 
grounded by the installer. Standard supply 
voltage is 115 volts A.C. However, optional 
A.C. voltages can be supplied on special order. 
A separate fused disconnect switch must be 
supplied and installed in the high voltage 
electrical supply line. The wire gauge size and 
electric supply must match the power 
requirements specified on the kettle's rating 
plate. The conduit-enclosed permanent copper 
wiring must be adequate to carry the required 
current at the rated voltage. Refer to the 
specification sheet  for  electrical specifications 
and location of electrical connections. 

INSPECTION 

Before unpacking visually inspect the unit for 
evidence of damage during shipping. If 
damage is noticed, do not unpack the unit, 
follow shipping damage instructions. 

SHIPPING DAMAGE INSTRUCTIONS 

If shipping damage to the unit is discovered or 
suspected, observe the following guidelines in 
preparing a shipping damage claim. 

1.     

Write down a description of the 
damage  or  the  reason  for suspecting 
damage as soon as it is discovered. 
This will help in filling out the claim 
forms later. 

2.    As soon as damage is discovered or 

suspected, notify the carrier that 
delivered the shipment. 

 

 

 

 

      - -IF YOU

 

SMELL GAS - -

 

1.  OPEN WINDOWS

 

2.  DO NOT TOUCH

 

    ELECTRICAL SWITCHES. 

3.  EXTINGUISH ANY OPEN FLAME.

 

4.

  CALL YOUR GAS

 

     SUPPLIER IMMEDIATELY.

 

Summary of Contents for KGL

Page 1: ...INSTALLATION OPERATION AND REPAIR MANUAL GAS KETTLE MODEL KGL KGL T CLEVELAND RANGE INC 1333 East 179th St Cleveland Ohio U S A 44110 216 481 4900 KET 07 9102 REV 0 222 01CO...

Page 2: ...ODE OR WITH THE NATIONAL FUEL GAS CODE ANSI 2223 1 1988 POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR...

Page 3: ...s and or the National Electric Code ANSI NFPA 70 1987 USA or the Canadian Electrical Code CSA Standard C22 1 Canada The kettle must be electrically grounded by the installer Standard supply voltage is...

Page 4: ...al Fuel Gas Code ANSI Z223 1 1984 USA or Installation Codes for Gas Burning Appliances and Equipment CANI B149 1 and B149 2 Canada Use a gas pipe joint compound which is resistant to L P gas Test all...

Page 5: ...ow water light should not be lit during kettle operation This light indicates that the water level has reached a critically low level and the gas burners have been automatically shut off by the kettle...

Page 6: ...al controls Always turn off equipment power before using water to wash equipment DO NOT HOSE DOWN THE KETTLE NOTE For more difficult cleaning applications one of the following can be used alcohol baki...

Page 7: ...m pressure gauge fittings We suggest mixing a 50 50 solution of liquid detergent and water while heating the kettle to at least 5 psi pressure Then shut off power to the kettle The soapy solution shou...

Page 8: ...ormer 120 16V 1 2 KE52690 Bushing 1 3 KE53469 Ignition module 1 4 KE00458 Solid state control 1 5 KE50753 Relay 1 6 KE53316 Safety thermostat 1 7 FI 05050 Brass nut 7 16 24 1 8 KE53436 Air switch 1 9...

Page 9: ...1 3 FI00151 Street elbow 1 2 2 4 KE51014 Check valve 1 5 FI00596 Nipple 1 6 FI05214 Cross tee 1 7 RT00370 Tubing 1 4 copper per ft 3 8 KE51723 Safety valve 50 p s i 1 9 FI00598 Nipple 1 10 FI052l6 Elb...

Page 10: ...trol valve N G 1 KE535151 Gas control valve L P 6 F01518 Shut off valve 1 7 Reducer 1 8 Pipe 1 9 Pipe 1 10 KE53441 Blower 1 11 Elbow 1 12 Pipe 1 13 Elbow 1 14 Plug 1 15 O Ring 1 16 KE53422 Spring 1 17...

Page 11: ...GAS CONTROL ASSEMBLY KETTLE...

Page 12: ...asher spacer 3 17 KE51891 Washer 1 18 KE517112 L H Bearing 1 19 KE51730 Tilt shaft bearing 1 20 FA19186 Screw hex socket 1 21 KE503752 Tilt shaft 1 22 KE50569 1 Temperature Control Assembly 1 KE50569...

Page 13: ...SIDE BOX ASSEMBLY KETTLE...

Page 14: ...assembly 1 KE509721 Draw off assembly for KDM 40 T 1 FA21008 Hex nut 1 FA95049 Wing nut FA11134 Screw for KDM 40 T 2 KE527551 Knob 1 3 KE52754 Hex nut 1 4 KE52753 Retainer 1 5 KE52752 Piston 1 KE53290...

Page 15: ...4 Hinge bearing 1 3 KE50823 Pin hinge 1 4 KE50820 Insert brass adjustment 1 5 KE50819 End piece 1 6 FA11507 Screws adjustment 2 7 FA11284 Bolts end block 2 8 KE50122 Spring 40 gal and under 1 KE50121...

Page 16: ......

Reviews: