background image

5.

POSTITIONING

Position the kettle in its permanent location, and level
the kettle by turning the adjustable flanged feet. Once
positioned and levelled, permanently secure the kettle's
flanged feet to the floor using lag bolts and floor
anchors (to be supplied by the installer).

SERVICE CONNECTIONS

Install service connections as required. Locations and
other data are shown on the Specification Sheet.

FOR POWER TILT UNITS ONLY

NOTE: Ensure the electrical supply matches the kettle's
requirements as stated on the rating label.

This kettle is built to comply with CE standards. Many local
codes exist, and it is the responsibility of the owner and
installer to comply with these codes.

STEAM

All steam plumbing to and from the kettle and steam
boiler should be thoroughly cleaned and inspected for
dirt and debris before final connection to the kettle are
made. 

Check the rating plate for the maximum steam pressure
that your kettle is rated for. If the steam supply pressure
exceeds the rated pressure, a pressure reducing valve
is required. The steam inlet is at the right side of the
kettle, as seen from the front.

CONDENSATE

A steam condensate trap must be plumbed to a drain,
using minimum 1/2" NPT plumbing. The condensate line is
limited to a maximum rise of 10 feet in order for the steam
pressure to adequately force the condensate through the
plumbing. Any higher rise requires a pump. 

If the steam boiler to which this kettle is installed has a
condensate return (closed loop system), a 1/2" steam
strainer, a 1/2" steam trap, and a 1/2" check valve must be
installed on the output (condensate) side of the kettle. 

POTABLE WATER

The water faucet (optional) with swing spout, requires 1/2
inch O.D. copper tube plumbing for hot or cold water
supplies to the faucet (SPK - cold water connection only,
DPK - hot and cold water connection). 

INSTALLATION CHECK

1.

Partially fill the kettle with water.

2.

Slowly turn the steam supply valve's knob to the
open position.

3.

Release the safety valve, ensuring that the steam
escapes freely. Stay clear of steam exhaust when
releasing the safety valve.

4.

Observe that the water in the kettle comes to a
boil.

5.

Close the steam supply valve. 

6.

Drain off the water in the kettle.

CLEANING

After installation the kettle must be thoroughly cleaned

A

B

C

D

1

Steam In

2

To Drain or Boiler 
Condensate Line

A

Strainer

B

Union

C

Pressure Reducing
Valve

D

Shut Off Valve

STEAM REQUIREMENTS

Kettle Cap.

Kettle

25 psi Steam

U.S. Gal.

Dia.

Lbs./Hr.

25

21"

70 

40

26"

100 

60

29.5"

150

p

Steam requirements are maximum per hour. 

p

If more than one unit is on the same line then add the
steam usage for each one to reach a total.

RECOMMENDED
PIPING
SCHEMATICS

(all service connections
shown supplied by others)

Summary of Contents for KDM-T

Page 1: ...roperty damage injury or death For your future reference Model ______________________________________ Serial ___________ ____________________________ Installation Operation Maintenance Parts Service T...

Page 2: ...onformer aux mesures de s curit normalis es de l industrie y compris mais sans s y limiter les r glementations de l OSHA les proc dures de d branchement verrouillage tiquetage relatives tous les servi...

Page 3: ...er des a rosols dans le voisinage de cet appareil alors qu il est en fonctionnement Cet appareil ne doit pas tre utilis par des personnes dont les capacit s physiques sensorielles ou mentales sont r d...

Page 4: ...sitivo de presi n Keep clear of pressure relief discharge Restez l cart de la soupape de suret Permanezca alejado de la descarga de presi n Do not lean on or place objects on lip Ne vous penchez pas s...

Page 5: ...rier s representative to examine the damage 4 Fill out all carrier claims forms and have the examining carrier sign and date each form APPROXIMATE WEIGHTS UNCRATING Caution Straps under tension and wi...

Page 6: ...rise of 10 feet in order for the steam pressure to adequately force the condensate through the plumbing Any higher rise requires a pump If the steam boiler to which this kettle is installed has a cond...

Page 7: ...here to hot cooking surfaces These types of foods should be placed in the kettle before heating is begun 5 Fill kettle with product to desired level 6 When the product has reached the desired temperat...

Page 8: ...a Disassemble the draw off valve first by turning the valve knob counter clockwise then turning the large hex nut counter clockwise until the valve stem is free of the valve body b In a sink wash and...

Page 9: ...ION 1 Perform daily startup inspection 2 Test pressure relief valve 3 Hand tilting Check handwheel for tightness If loose tighten Allen screw Power tilting Check that kettle tilts smoothly Grease as d...

Page 10: ...leak must first be determined Leaks from around the valve stem are corrected by simply replacing the O ring Faulty seating of the valve stem disc against the valve body may cause dripping from the va...

Page 11: ...ace if necessary 2 Defective jack or capacitor Remove cover from upper junction box This will access the wire connections to the power jack Measure the resistance across each of the three wires It is...

Page 12: ...nd Repair Centre for replacement parts service or information regarding the proper maintenance and repair of your cooking equipment In order to preserve the various agency safety certification UL NSF...

Page 13: ...16 1 16 FA15009 Shoulder Bolt 3 4 X 2 1 2 5 8 11 1 17 SK50680 Tilt Switch 1 18 KE51688 Power Jack c w Motor 1 19 SE50025 Motor Power Jack 1 20 KE51366 1 Magnetic Door Latch used after October 11 2001...

Page 14: ...MODIFIED CORRECTIONAL PACKAGE 1 6 FA05002 24 O RING TD 1 5 1 FA05002 38 O RING TD 3 1 7 SE50005 VALVE BODY TD 1 5 1 KE50973 VALVE BODY TD 3 1 1 2 3 4 5 6 7 8 TANGENT DRAW OFF VALVES ITEM NO PART NO D...

Page 15: ...6 FA11258 HEX CAP SCREW 2 7 FA31029 LOCK WASHER 2 8 FA21008 HEX NUT 2 9 KE51401 SINGLE PANTRY BODY c w item 13 1 10 KE50335 ADAPTER WASHER 1 11 KE51403 DOUBLE PANTRY BODY c w item 13 14 1 12 SE50447...

Page 16: ...80TSH SPK7 KE54159 KE50825 7 KEL40 60TSH DPK7 KDT6 ON SD OR ST SPK8 KE50825 8 DPK8 TKET KET3 6 12 SPK9 KE54159 KE50825 9 DPK9 KDL125 150T SPK10 KE54159 KE50825 10 KGL40 60 80T DPK10 KGL40TSH HAMKGL60...

Page 17: ...GHT 0 162DIA 16 COILS 1 1 4 KE50823 1 HINGE PIN LIGHT SPRING 1 1 KE50823 2 HINGE PIN MODIFD HEAVY SPRING 1 1 5 KE50824 HINGE BEARING MODIFIED 1 1 1 1 6 KE50819 1 HINGE END PIECE LHS 1 1 KE50819 2 HING...

Page 18: ...itchencare com To learn how Welbilt Foodservice and its leading brands can equip you visit our global web site at www welbilt com then discover the regional or local resources available to you Every n...

Reviews: