background image

SECT.

XIV

PAGE 

10

1004

Litho in USA

Cleveland Range reserves right of design improvement or modification, as warranted.

 

 

 

 

 

 

  

  

 !

"# $

 

  

 

 $"

 $"

  

#%%

  

#%%

#   

 

  

  

 #     #  

"&  #  # # 

"    #   

  

DIMENSIONS

MODEL

A

B

C

D

E

F

G

ELECTRICAL PER KETTLE - 

R.P.M.

208V/ 3PH/60Hz

HA-MKDL-60-CC-T

59"

36 3/4"

22"

50"

84"

48"

5"

15 AMPS

3-22

HA-MKDL-100-CC-T

72"

42"

25"

57"

93"

53"

5"

18 AMPS

3-20

HA-MKDL-150-CC-T

75"

47 1/2"

29"

65"

107"

58 1/2"

5"

18 AMPS

3-18

HA-MKDL-200-CC-T

80 1/2"

52"

32"

70 1/4"

115"

63 1/2"

5"

25 AMPS

3-18

HA-MKDL-300-CC-T

92"

65 1/2"

34"

82"

106"

68 1/2"

5"

25 AMPS

3-16

UTILITY CONNECTIONS

CHILLED

CHILLED

COLD

WATER

WATER

POTABLE

HOT

CONDENSATE

AIR

MODEL

INLET

RETURN

WATER

WATER

RETURN

DRAIN

INLET

STEAM

HA-MKDL-60-CC-T

3/4"

3/4"

3/4"

3/4"

1/2"

3/4"

1/2"

3/4"

15 GPM

15 GPM

15 GPM

1 CFM

320 lbs/hr

HA-MKDL-100-CC-T

1"

1"

3/4"

3/4"

3/4"

1"

1/2"

1"

20 GPM

20 GPM

20 GPM

1 CFM

525 lbs/hr

HA-MKDL-150-CC-T

1 1/4"

1 1/4"

3/4"

3/4"

1"

1 1/4"

1/2"

1 1/4"

20 GPM

20 GPM

20 GPM

1 CFM

780 lbs/hr

HA-MKDL-200-CC-T

1 1/4"

1 1/4"

3/4"

3/4"

1"

1 1/4"

1/2"

1 1/4"

25 GPM

20 GPM

20 GPM

1 CFM

1050 lbs/hr

HA-MKDL-300-CC-T

1 1/2"

1 1/2"

3/4"

3/4"

1"

1 1/2"

1/2"

1 1/2"

30 GPM

20 GPM

20 GPM

1 CFM

1575 lbs/hr

** HOT FILL WATER IS OPTIONAL

65 PSI STEAM OPERATING PRESSURE IS RECOMMENDED

**

MINIMUM

CLEARANCE

FOR

KETTLES

FRONT

36"

SIDE

12"

REAR

12"

ELECTRICAL POWER
TO AND FROM 
CONTROL PANEL
• CONTRACTOR

MUST CUT ENTRY
HOLE

• TOP OR BOTTOM

POWER ENTRY
RECOMMENDED

• MUST USE PROPER

CONNECTIONS TO
MAINTAIN U.L.
LISTING

(NOT TO SCALE)

Reviews: