
TROUBLESHOOTING CHART
COMPLAINT
6. GENERATOR OVERFILLS & TEE POWER SWITCH IS ON
(WATER RUNS OVER INTO THE COOKING COMPARTMENT FROM STEAM
DISCHARGE
)
POSSIBLE CAUSES
I.
If no voltage is measured across either the purge solenoid
coil or the fill solenoid coil.
A.
Foreign material or scale could be physically keeping
the plunger from seating, thus allowing water to
continually enter the generator through one of the
solenoids.
II.
If 120 volts is measured across the purge solenoid
coil.
A. Purge timer contacts are stuck closed.
III. If 120 volts is measured across the fill solenoid coil.
A. Faulty liquid level control board.
B.
Faulty probe.
C.
Broken or poor ground connection to common terminal
on levelcontrol board.
D. Broken or poor probe wire connection from level board
to the probe.
E. Scale buildup on probe.
F. Heavy scale buildup in
generator.