Cleveland 24CSM Series Supplementary Manual Download Page 9

Replace the

 on/off rocker

switch

Yes

Connect power

to steamer.

No

Is the red light on

in the power

switch?

Is there power to

the steamer?

Is there water in

the sight glass?

Yes

See

Steamer won't

fill.

No

PROBLEM:

Steam Coil Boiler

won't build

pressure

No

Boiler won't build

pressure

Is the Amber light

on in the reset

switch?

Is there 120 VAC

between

terminals L2 and

HTR on the water

board?

Is there 120 VAC

between terminals

L2 and HTR on the

water board with a

jumper between

Low and C?

Is there 120 VAC

to terminal 6 on

the latching relay?

Repair

 or Replace the

probe circuit.

Replace the
water board

Replace the

Reset switch

Yes

After depressing
the reset switch,

does the Amber

light go off?

Does this boiler

have the optional

Secondary  Low

Water Cut Out?

With the High

Limit pressure

switch

temporarily

bypassed, does

the Amber light go

off when the reset

switch is

depressed?

Yes

No

No

Yes

No

Replace

 the high limit

pressure

 switch

With the SLW CO

switch

temporarily

bypassed, does

the Amber light go

off with the reset

switch depressed?

No

Yes

Yes

Replace the

SLWCO switch

With a jumper

from terminal 5 to

9 on the latching

relay, does the

Amber light go out

with the reset

switch depressed?

No

No

Replace the

latching relay.

Yes

Yes

Is there 120 VAC

to the coil of the

steam solenoid?

No

Yes

Replace the

latching relay

No

Yes

Is there 120 VAC

to the coilof the
steam solenoid

with the operating

pressure switch

temporarily

bypassed?

No

Replace the

latching relay

Replace

 the operating

pressure

switch

Does the Steam

solenoid open?

Yes

Is there an steam

at the steam coil?

Yes

With

Elements heating

the water, the

Boiler is making

steam.  Check for

leaks.

Is there a lot of

steam coming out

the drain?

Replace the

steam trap for

the boiler.

No

Supply steam

to the steamer.

No

Replace the

steam solenoid

No

No

Yes

Yes

Is the steam trap

for Incoming

steam opening to

remove air and

water from coil?

Yes

Yes

Yes

Replace the

steam trap for

the coil

No

Summary of Contents for 24CSM Series

Page 1: ...technical and technological changes revisions or updates Cleveland Range LLC assumes no liability or responsibility regarding errata changes revisions or updates Qualified Cleveland Range LLC Authoriz...

Page 2: ...Cleveland Range LLC 1333 East 179th St Cleveland Ohio U S A 44110 Ph 1 216 481 4900 Fx 1 216 481 3782 Visit our Web Site at www clevelandrange com...

Page 3: ...ther the high pressure switch or the low water cut off float switch opens the latch circuit opens x When the contacts close the amber light will energize and the process may begin again x The relay co...

Page 4: ...the unit is turned off by depressing the red rocker switch x 115 VAC is removed from the heat circuit x 115 VAC is removed from the drain circuit and the normally open drain valve opens allowing the u...

Page 5: ......

Page 6: ...contact of the high pressure switch to the amber reset switch energizing the amber light 3 When the momentary amber switch is depressed 115 VAC is sent to the ice cube relay closing it x The relay la...

Page 7: ...seconds the WF terminal is energized and the water fill circuit begins again 8 When the unit is turned off by depressing the red rocker switch x 115 VAC is removed from the heat circuit x 115 VAC is r...

Page 8: ......

Page 9: ...ressed Yes No No Yes No Replace the high limit pressure switch With the SLWCO switch temporarily bypassed does the Amber light go off with the reset switch depressed No Yes Yes Replace the SLWCO switc...

Page 10: ...s water leaving the fill solenoid Replace wiring to drain solenoid Does the steamer have the optional intermittent blowdown timer Replace the wiring to the intermittent blowdown timer Is there 120 VAC...

Page 11: ...PROBLEM Steam Coil Boiler Stops Producing Steam Boiler stops steaming Does the amber light in the reset switch come on Is the temperature sensitive dot surrounded by a yellow circle on the water board...

Page 12: ...eplace the fill solenoid With a jumper across terminals HI and C on the waterboard is there 120 VAC between L2 and WF Replace the water board Yes The probe circuit is open Check continuity of the prob...

Reviews: