Cleveland 24CSM Series Supplementary Manual Download Page 11

PROBLEM:

Steam Coil

Boiler Over

Pressurizes

(15# Safety

valve opens)

Boiler over

pressurizes

Does operating

pressure switch

open at proper

setting (check

service manual for

that steamer)?

Replace

operating

pressure

switch

No

Does the steam

solenoid stay open

with operating

pressure switch

open?

Yes

Replace steam

solenoid

Does the pressure

in the gauge

continue to rise

with no voltage to

contactor coil?

No

Replace the

weeper valve.

Does the 15#

safety valve open

with little or no

pressure on the

gauge after it has

been replaced?

No

Replace the

safety valve.

No

Scale is blocking the

plumbing to the gauge.

Delime the boiler.

PROBLEM:

Steam Coil Boiler Stops Producing Steam

Boiler stops

steaming

Does the amber
light in the reset

switch  come on?

Is the temperature

sensitive dot

(surrounded by a

yellow circle) on

the water board

white?

Replace

 the water board.  It has

reached a temperature of

over 180
degrees.

Yes

No

No

Does boiler have

the optional

Secondary Low

Water Cut Out?

Yes

Are the probes

covered with

scale?

No

Delime boiler

Is high pressure

switch opening

prematurely?

Replace high

pressure switch

Replace the

water board

Yes

No

Yes

No

Will Boiler stop

making steam

with SLW CO

temporarily

bypassed?

Yes

Yes

Does SLW CO

open and close as

float is moved up

and down?

No

Install delay

timer for
SLWCO

Yes

Replace

Secondary Low

Water Cut Out

switch.

No

Yes

Replace

operating

pressure

switch.

Does steam coil

leak?

Yes

Yes

Replace steam

coil

Yes

No

Summary of Contents for 24CSM Series

Page 1: ...technical and technological changes revisions or updates Cleveland Range LLC assumes no liability or responsibility regarding errata changes revisions or updates Qualified Cleveland Range LLC Authoriz...

Page 2: ...Cleveland Range LLC 1333 East 179th St Cleveland Ohio U S A 44110 Ph 1 216 481 4900 Fx 1 216 481 3782 Visit our Web Site at www clevelandrange com...

Page 3: ...ther the high pressure switch or the low water cut off float switch opens the latch circuit opens x When the contacts close the amber light will energize and the process may begin again x The relay co...

Page 4: ...the unit is turned off by depressing the red rocker switch x 115 VAC is removed from the heat circuit x 115 VAC is removed from the drain circuit and the normally open drain valve opens allowing the u...

Page 5: ......

Page 6: ...contact of the high pressure switch to the amber reset switch energizing the amber light 3 When the momentary amber switch is depressed 115 VAC is sent to the ice cube relay closing it x The relay la...

Page 7: ...seconds the WF terminal is energized and the water fill circuit begins again 8 When the unit is turned off by depressing the red rocker switch x 115 VAC is removed from the heat circuit x 115 VAC is r...

Page 8: ......

Page 9: ...ressed Yes No No Yes No Replace the high limit pressure switch With the SLWCO switch temporarily bypassed does the Amber light go off with the reset switch depressed No Yes Yes Replace the SLWCO switc...

Page 10: ...s water leaving the fill solenoid Replace wiring to drain solenoid Does the steamer have the optional intermittent blowdown timer Replace the wiring to the intermittent blowdown timer Is there 120 VAC...

Page 11: ...PROBLEM Steam Coil Boiler Stops Producing Steam Boiler stops steaming Does the amber light in the reset switch come on Is the temperature sensitive dot surrounded by a yellow circle on the water board...

Page 12: ...eplace the fill solenoid With a jumper across terminals HI and C on the waterboard is there 120 VAC between L2 and WF Replace the water board Yes The probe circuit is open Check continuity of the prob...

Reviews: