I.2
Meaning of the Light indicator
The red light allows viewing of sensor’s status and the presence of smoke or carbon monoxide.
This indicator takes the following states according to procedures describes in the table below:
Mode
State
Description
Defa ult
Wi thout s eparate announcement, the association remains off.
Sta rt-up
2 ti mes
At s ta rtup, the sensor flashes twi ce slowly.
Identification
The ti me is gi ven
i n the fra me
Identi fy
On recei ving i dentify command, the sensor blink slowly as the
i dentification time isn’t exceeded.
Ma nual s tart of the
a s sociation phase
Up to 20 s econds The device blinks s lowly when he researches a coordinator.
Pa i ri ng OK
2 s econds
Once a ssociated, the s ensor turns on 2 s econds.
Smoke alarm or carbon
monoxi de alarm
conti nues
If the s ensor detects the s moke or a n a bnormal level of ca rbon monoxide,
the red l ight turns on until the end of the alarm.
I.3
Specifications
Stack ZigBee™
ZigBee™ Pro 2007 Can operate on all 16 channels ZigBee
Radio range
30 m (inside)
Smoke detector
1% ~ 5% PI OBS
CO detector
100 ±50ppm
Temperature of use
5 to +40 °C
Sound
85 dB à 3m
Power
1 battery 9V 6F22
Battery Life
~ 1 year
Dimensions
Ø110mm – height 37mm
Turn off
Turn on during 2s
Slow flashing
Fast flashing
Clignotement rapide
Legend :