![Cleode ZGAS User Manual Download Page 17](http://html1.mh-extra.com/html/cleode/zgas/zgas_user-manual_2622567017.webp)
User Manual : ZGAS
CLEODE
page
17
sur
21
IV.
Software interface
IV.1
Presentation
Le ZGas contains an application type IAS Zone denied in the standard Home Automation (See document [3]).
This is fully compliant with the ZigBee® Pro 2007 and Home Automation profile. For more details on the data
exchanged, please refer to the documents [1], [2] and [3].
IV.2
Application
IV.2.1
Description of the application
Device ID : IAS Zone
Endpoint : 1
Clusters :
Server
Client
Basic (0x00)
/
Power Configuration (0x01)
/
Identify (0x03)
/
Alarms (0x09)
/
IAS Zone (0x0500)
/
IAS Warning Device (0x502)
/
IV.2.2
Description of clusters
Here is a brief description of clusters and attributes implemented in the ZGas. For more details on the operation
of these, please refer to the document [1].
IV.2.2.1
Cluster Basic
This Cluster provides information of version, manufacturer, model, etc…
Attributes
Attributes identifier
ZCLVersion
0x0000
ApplicationVersion
0x0001
StackVersion
0x0002
HWVersion
0x0003
ManufacturerName
0x0004
ModelIdentfier
0x0005