Clenergy SPH Installation and Operation Manual
5. Communication interfaces
The SPH inverter is equipped with an RS232 and USB communication interface
as standard. A communication slot is also provided for advanced
communications options.
The status of the inverter can be monitored via the communications interfaces
using a PC with the
monitoring software “Solar control”. The software is free.
The software will be downloaded from
www.clenergy.com.au/download.php
Download the “SPH - Monitoring Software V1.26” and install in your computer.
Installation and service technicians can also change the unit setting and
download new firmware via the RS232 interface using “PV_Reflash” software.
1.
RS232: The SPH inverter is equipped with a 3-wire RS232 interface using a
DB9 socket. This is located under the RS232 cover on the bottom of the unit.
The table below defines the connector pin functions. N.C. means “No
Connection”.
Pin
Assignment Description
1
N.C.
2
TxD
3
RxD
4
N.C.
5
Common
6
N.C.
7
N.C.
8
N.C.
9
N.C.
2.
Optional communication slot: This slot is a very powerful expansion slot. The
SPH unit can accept a special communication function card in this slot. There
are 2 kinds of cards available now. One is an RS485 card and the other is a
SNMP (Simple Network Management Protocol) card. In the future, other
cards may be developed. For detailed information, please refer to the
instruction manual of the individual card.