3.2 Precautionary Measures for Stainless-Steel Fastener Installation
Improper operation may lead to the deadlock of bolts and nuts. Follow the steps below to reduce this
risk.
3.2.1 Reduce the friction coefficient
(
1) Ensure that the thread surface is clean (no dirt or contaminant).
(2) Apply lubricant (grease or 40# engine oil) to fasteners prior to tightening to avoid galling or
seizing in the threads.