18
7.2 If required
Check and if necessary. replace /cleanse
View window
-Cover lenses
-If necessary window glass – see 6.4.6
Gloves
7.3 After max. 8 h of blasting
Check and if necessary. replace /cleanse
Door interlock
-Open doors
- Press pin (1). It has to return from alone.
Empty dust container.
- Could be necessary already after one hour
Media recovery system
(Reclaimer).
-Empty screen
Turn off exhauster. This may be necessary more often
- Screen magnet .
Nozzle and nozzle holder
Check gasket for wear and replace if it’s necessary
7.4 After max. 50 h of blasting
Check and if necessary. replace /cleanse
(1) Blast gun and nozzle
Nozzle gasket.
(2) Moisture separator.
Clean filter and sight glass with soap and warm water
(3) Air hoses and blast hoses.
- Gaskets of couplings for wear
-Blast hose by hand for soft spots
(4) Blast pot
- Pop up valve for wear by hand
-Check wear oft he pop-up valve by by palpation with fingers
7.5 After max. 150 h of blasting
(1) Gasket on cabinet doors.
(2) Filter cartridge.
- see 6.4.5
7.6 After other periodes of time
replace (even without wear) after maximal
Blsat hoses
6 years
Remote control hoses
6 years
Air hoses – external air supply
6 years