background image

DO NOT OPERATE THE ECOGUM PRX1 WITHOUT READING AND UNDERSTANDING THE 
OPERATING INSTRUCTIONS. IF THE ECOGUM PRX1 IS OPERATED INCORRECTLY IT CAN 
POSE DANGER TO THE OPERATOR AND OTHERS AND WILL INVALIDATE THE 
MANUFACTURERS WARRANTY. BEFORE USE, READ AND UNDERSTAND THE FOLLOWING:
 

1. 

A risk assessment for the works to be undertaken.

2. 

ECOGUM  MSDS Chemical Data Sheet.

3. 

Risk Assessment for ECOGUM Chemical use.

4. 

ECOGUM LPG data sheet.

IMPORTANT NOTICE:

Before inserting the LPG Gas and gum removal chemical correctly fit the rucksack to the 
operator by adjusting the straps to fit. The rucksack has been designed to be kept upright at all 
times when the LPG and gum removal chemical are inserted. This is important to the operation 
of the Ecogum PXR1 Workman.

Cautions when using the ECOGUM PRX1:

Keep the unit upright at all times when operating or when chemical or gas is inserted. 

The rechargeable battery has been designed to be fully charged BEFORE each use. 

Only use the ECOGUM approved solution and ECOGUM LPG for the safe use of the 
ECOGUM PRX1. Using other consumable items in the ECOGUM PRX1 invalidates the 
warranty and will lead to damage of the internal parts of the ECOGUM PRX1.

Make sure the operator has read and understood these instructions before attempting 
to use the ECOGUM PRX1 and is fully trained in its operation.

ECOGUM LPG gas consumption will vary slightly according to atmospheric pressures. The 
service pack contains 2 x ECOGUM LPG gas bottles, which will last approximately 8 hours.

ECOGUM chemical (2 Litre) will last for approximately 2 hours of continual use. 4 x ECOGUM 
chemical bottles will last for approximately 8 continual hour’s operation.

Brass brushes will wear according to the surface being cleaned. Each brass brush will last for 
approximately 1 to 1.5 hours. 6 x brass brushes will last for 8 hours continual operation of the 
ecogum PRX1. 

Choose a brass brush for solid urban surfaces such as concrete, natural stone, tarmacadam, 
asphalt and other common urban surfaces. Choose a nylon brush for surfaces such as wooden 
flooring, entrance matting and heavy-duty carpet.

IMPORTANT NOTICE:

Always complete a test patch on the above surfaces to make sure no damage occurs to the 
flooring or surface.

Operators Instructions ECOGUM PRX1:

Consumable Items: 

Summary of Contents for GUMPAK

Page 1: ... CHEWING GUM REMOVAL OPERATOR MANUAL Clemas Co Unit 5 Ashchurch Business Centre Alexandra Way Tewkesbury Gloucestershire GL20 8NB Tel 01684 850777 Fax 01684 850707 Email info clemas co uk Web www clemas co uk ...

Page 2: ...UM PRX1 Using other consumable items in the ECOGUM PRX1 invalidates the warranty and will lead to damage of the internal parts of the ECOGUM PRX1 Make sure the operator has read and understood these instructions before attempting to use the ECOGUM PRX1 and is fully trained in its operation ECOGUM LPG gas consumption will vary slightly according to atmospheric pressures The service pack contains 2 ...

Page 3: ...om the gum and use a broom to sweep across the area to ensure the gum has been destroyed or if further cleaning is needed As gum deposits are all different there will be varying times taken to destroy each piece Turn the red switch of which will isolate the machine Remove the Gas and Chemical bottles from the Ecogum system Turn the switch on to drain the unit until there is no fluid coming from th...

Page 4: ...Safety Data Sheet according to 1907 2006 EC Article 31 GUM REMOVER SOLUTION PRX1 R e v o l u t i o n a r y C h e w i n g G u m R e m o v a l Instruction Manual ...

Page 5: ...Safety Data Sheet according to 1907 2006 EC Article 31 GUM REMOVER SOLUTION PRX1 R e v o l u t i o n a r y C h e w i n g G u m R e m o v a l Instruction Manual ...

Page 6: ...Safety Data Sheet according to 1907 2006 EC Article 31 GUM REMOVER SOLUTION PRX1 R e v o l u t i o n a r y C h e w i n g G u m R e m o v a l Instruction Manual ...

Page 7: ......

Reviews: