20
P1885E/EN 2008-07
86d_Reparatur en bedingt.fm, 27.10.2010
Repair instructions
7
7.3
Disassembling the pulse unit
Abb. 7-1
7.4
Assembling the motor unit
CAUTION!
Skin irritation in case of direct contact with oil.
Wear protective gloves.
CAUTION!
Hydraulic blade is under spring pressure!
Wear protective goggles.
NOTE
Permitted only if filling is guaranteed with oil filling
device, see 6.3 Refilling oil, page 16. The pulse unit
must have cooled to room temperature.
CAUTION!
•
Always carry out assembly according to the exploded drawing, see 8 Spare parts, page 25.
Incorrect assembly causes uncontrollable reactions, such as unexpected startup or ejection of parts.
•
Tighten all screwed joints of the tool carefully, according to the specifications.
NOTE
To prevent damage, lubricate the gaskets and O-rings using grease (order no. 914392) before
assembly.
<65>
<D>
Size 1/2"