1994b_1_5_en-bedingt.fm, 12.06.2014
P1991BA/EN 2014-06
11
Before initial operation
4
Oils according to DIN 51524 / ISO 3498
4.2
Change air inlet: top / bottom (only on 11PHHA)
When delivered, the air inlet is at the BOTTOM and sealed with a screw plug. To change the air supply from
top to bottom:
Remove the air strainer from the air inlet at the TOP (do not discard), see 8.2 Pistol grip 11PHHA…,
page 30, Detail
X
.
Remove screw plug from BOTTOM. When doing this, counterhold with wrench (WAF 17).
Seal the air inlet at TOP with screw plug in accordance with specifications.
4.3
Connect the tool
Connect the tool to the compressed air line.
Maximum screwing-in torque = 40 Nm. Reaction torque at flat end. Counterhold with wrench (WAF 17).
Activate compressed air: 620 kPa.
4.3.1
Testing
4.4
Setting up the tool
The tool must be configured for the desired rundown.
Order
no.
Packaging
unit
Liter
Name
ARAL
BP
elf
ESSO
INA
Mobil
Klüber
SHELL
933090
2
HL32
Aralub
EE 100
Energol
HL 32
Polyelis 32
Olna 32
Nuto
H 32
Hydraol
32A
D.T.E.Oil Light
Vactra Oil Light
Crukolan 32
Molina 32
Molina 22
CAUTION!
The air hose can come off by itself and whip around uncontrollably.
Shut off the compressed air before making the connection.
Fully open exhaust air throttle anti-
clockwise.
Check speed at output drive:
>6500 rpm
Summary of Contents for 11PHH
Page 4: ...4 P1991BA EN2014 06 1991a_ Deckblatt_en fm 12 06 2014...
Page 14: ...14 P1991BA EN2014 06 1994b_1_5_en bedingt fm 12 06 2014 Before initial operation 4...
Page 20: ...20 P1991BA EN2014 06 1994c_Wartung_en bedingt fm 12 06 2014 Maintenance 5 Empty side...
Page 26: ...26 P1991BA EN2014 06 1994d_Reparatur_en bedingt fm 12 06 2014 Assembly instructions 7...