Introduction 

The  operation  of  the  LPSA  Air  Dryer  is  based  on  the  pressure  swing  adsorption  (PSA)  cycle 
using a synthetic zeolite molecular sieve.  The LPSA Air Dryer is capable of delivering dry air 
flows up to 20 standard cubic feet per hour (SCFH) for LPSA20, and 60 SCFH for LPSA60 at 

60

°

F to 

90

°

F dewpoint at rated conditions.  The main components of the LPSA Air Dryer are 

a SeQual ATF LPSA Module and an oil-less air compressor.   

 
Installation 

IMPORTANT:

 There are packaging materials that must be removed from under and around the 

compressor.  Do not attempt to operate the LPSA Air Dryer without removing these packaging 
materials as damage may result. 
 
Ensure  that  there  is  sufficient  access  space  around  the  LPSA  Air  Dryer  so  that  normal 
maintenance and service can be performed.  Also ensure that there will be a free flow of cooling 
air around the compressor.  Connect the unit to a grounded power source rated for the voltage 
and current requirements stated on the label on the unit. 
 

IMPORTANT:

  The  location  of  the  LPSA  Air  Dryer  must  be  well  ventilated.    Refer  to  the 

recommendations  in  the  Compressed  Gas  Association  Guide  P-8.1,  “Safe  Installation  and 
Operation of PSA and Membrane Oxygen and Nitrogen Generators.”  Contact ClearWater Tech 
if further assistance is needed. 
 

IMPORTANT:

  Choose  a  location  for  the  LPSA  Air  Dryer  that  does  not  allow  rain  or 

condensation to contact the unit.  
 

Dry Air Hook-up 

The dry air connection is a 1/8 inch female National Standard Pipe Thread (NPT) and is located 
on the front of the LPSA Air Dryer.  The hex nut bulkhead fitting should be stabilized with a 7/8 
inch wrench to prevent rotation when making your connection to the unit. 

 

Summary of Contents for LPSA20

Page 1: ...LPSA60 ClearWater Tech LLC Integrated Ozone Systems 850 E Capitolio Way San Luis Obispo Ca 93401 805 549 9724 Fax 805 549 0306 E mail service cwtozone com www cwtozone com Copyright 2007 ClearWater Tech LLC Reproduction of any kind is prohibited LIT205 REV060810 ...

Page 2: ...r Dryer should be installed and operated per the Compressed Gas Association Guide P 8 1 Safe Installation and Operation of PSA and Membrane Oxygen and Nitrogen Generators Patents Trademarks and Copyright The LPSA Series Air Dryers are protected by the following US Patents 4 925 464 5 112 367 5 114 441 5 268 021 5 366 541 5 593 478 5 370 778 Re 35 099 Other patents pending ATF is a registered trade...

Page 3: ...that normal maintenance and service can be performed Also ensure that there will be a free flow of cooling air around the compressor Connect the unit to a grounded power source rated for the voltage and current requirements stated on the label on the unit IMPORTANT The location of the LPSA Air Dryer must be well ventilated Refer to the recommendations in the Compressed Gas Association Guide P 8 1 ...

Page 4: ... 220VAC and 240VAC units may be provided with a standard NEMA rated cord The plug on this cord must be cut off and the unit hard wired to main power Color codes Black Line or L1 White Neutral or L2 Green Ground or Earth Set the outlet dry air flow to 20 SCFH or less for LPSA20 and 60 SCFH or less for LPSA60 Do not exceed rated capacity IMPORTANT The flow meter installed on the LPSA Air Dryer is se...

Page 5: ...0 F to 90 F dewpoint at 5 psig LPSA60 60 SCFH at 60 F to 90 F dewpoint at 5 psig Electrical Input 120 VAC 60 Hz 220 VAC 50 Hz LPSA20 4 AMPS 2 AMPS LPSA60 4 AMPS 2 AMPS Environment The LPSA Air Dryer is not weatherproof It must be installed where rain and condensation are not allowed to contact the unit Operating temperature 40 F to 95 F Storage temperature 0 F to 140 F Humidity 0 to 95 RH Barometr...

Page 6: ...t ClearWater directly for further information on other parts Service Parts Service Part Quantity LPSA20 Part No LPSA60 Part No ATF Module 120 220VAC 50 60Hz 1 PDATF20 PDATF60 Compressor 120VAC 60Hz 1 AC80 AC81 Compressor 220VAC 50Hz 1 AC85 AC86 Compressor Inlet Filter 1 OXS350 OXS350 Compressor Rebuild Kit 1 OXS356 OXS356 Compressor Relief Valve 1 OXS362 OXS362 Exterior Filter 1 OXS370 OXS370 ...

Page 7: ...ith the product and or part must be clearly described The RGA number must appear prominently on the exterior of the shipped box es The product and or part must be packaged either in its original packing material or in comparable and suitable packing material if the original is not available You are responsible for paying shipping charges to CWT and for any damages to the product and or part that m...

Reviews: