background image

RoboFryBox One

Deep-fat fryer

User manual

Read this manual before use!

PDF version of this manual is available on www.robolabs.pro

Summary of Contents for RoboFryBox One

Page 1: ...RoboFryBox One Deep fat fryer User manual Read this manual before use PDF version of this manual is available on www robolabs pro ...

Page 2: ...Safety requirements DO NOT operate without oil DO NOT operate with water Burn hazard Hot oil Only instructed personnel is allowed to oper ate the equipment 2 ...

Page 3: ...ter 8 1 6 5 Low oil and water detection 8 2 Intended use 9 2 1 Normal operation order 9 2 2 Shutting down 10 2 3 Adding oil 10 2 4 Changing oil 10 2 5 Water in oil Err4 11 2 6 Oil temperature adjustment 11 2 7 Program timers adjustment 11 3 Cleaning and maintenance 12 3 1 Cleaning instructions 12 3 2 Filters replacement 14 4 Transportation storage 14 5 Quality control check 15 6 Warranty obligatio...

Page 4: ...8 Technical service 17 8 1 Error codes 17 8 2 Setup mode 18 8 2 1 Basket operation check 18 8 2 2 Fine adjustment 18 8 3 Electric components layout 20 4 ...

Page 5: ...ating oil volume 8 liters Product load up to 500 g per basket Heat up time not more than 20 min Rated voltage 1P 230 V AC Rated frequency 50 Hz Rated power 3300 W Net weight 50 kg Dimensions LxWxH 350x545x820 mm 1 2 Delivery set Unit 1 pc Leg 4 pcs Deflector 1 pc Documentation 1 set 1 3 Assembling 1 Carefully unpack the machine check delivery set and remove protec tive film from all surfaces 2 Mou...

Page 6: ...sing related to RH in creasing for example 90 of RH at 20 C Altitude above sea level should not exceed 1000 m 1 5 Power requirements Power outlet MUST have grounding contact If supply cord damaged it must be replaced by manufacturer service agent or qualified persons in order to avoid hazard Connections must be done by qualified electri cian ONLY Use IEC 60309 2P PE 16 A plug Equipotential bonding...

Page 7: ...oor 2 Latch 3 Light box 4 Control panel 5 Loading tray 6 Deflector 7 Leg 8 Paper carbon filter assembly 9 Grease filter 10 Oil tank 11 Basket 12 Heating element 13 Drain valve 1 6 2 Control panel Control panel has the following items 1 ON OFF button 2 4 digit display 3 program buttons 7 ...

Page 8: ... filter second stage is a paper HEPA filter and third stage is a carbon filter Up to 98 of smallest particles less than 0 3 micron are retained 1 6 5 Low oil and water detection The machine can detect low oil and water in oil If oil is low then the machine will cut off the power supplied to the heaters and notify the op erator If considerable amount of water presents in the oil then machine will a...

Page 9: ...lation and backlight are on Heating progress is to be visualized on the display In the beginning of heating process display shows four blinking letters HHHH While temperature is rising up there are less H letters blinking Once the set point is reached display shows the temperature set value 180 for example The machine is now ready for operation To prepare a portion of product do the following 1 Op...

Page 10: ...el Do the following 1 Turn the machine off 2 Close loading tray 3 Open the door 4 Carefully pour oil into the frying pan up to the MAX mark 5 Close the door 6 Turn the machine on 2 4 Changing oil The same load of oil can be used for certain time which depends on the product used settings and other factors It is recommended to use special tool or testing strips to find out when oil should be change...

Page 11: ...and turn the machine on 2 6 Oil temperature adjustment 1 Turn the machine off 2 Press and hold ON OFF button until Pr appears on the display then release the button 3 Press ON OFF button again Pr C appears on the display Press button 1 to decrease or button 2 to increase the value By default the temperature is 180 C 4 The machine automatically returns back to standby mode after 10 sec of idle 2 7 ...

Page 12: ...g DO NOT use aggressive solutions for cleaning DO NOT use sharp tools or items for cleaning Wait until oil is cooled down The purpose of cleaning and maintenance is to keep the machine operable during the entire service life and to meet hygiene requirements 3 1 Cleaning instructions In the end of a day do the following 1 Let the oil to cool down 2 Attach oil drain hose to the valve get ready a dra...

Page 13: ... up the pin on the left side of the chamber and then put the heater down 8 Take out the frying tank Pour the oil remains to the drainage con tainer see Fig 4 9 Take out paper carbon filter assembly see Fig 5 DO NOT wash or soak the filters 10 Take out the grease filter see Fig 6 11 Thoroughly wash basket tank heaters assembly internal surfaces of the chamber grease filter loading tray and deflecto...

Page 14: ... Depending on intensity of machine operation the period may vary 4 Transportation storage The equipment may be transported by any kind of covered vehicle in accordance with transportation rules for this kind of vehicle Ambient temperature during the transportation and storage must be between mi nus 25 C and 55 C 14 ...

Page 15: ...rial The equipment is made with accordance to mandatory requirements of the state standards actual technical documentation and approved for use QC Engineer STAMP HERE Signature Full name DD MM YYYY Actuator factory parameters A1 A2 A3 A4 15 ...

Page 16: ...y manufacturer at any time due to improvements and or other reasons Technical specifications stated in this document are intended to act as a reference point which is necessary to evaluate suitability of the equipment for the customer s needs and are not the subject of warranty policy The information stated in this document has been thoroughly checked and considered as accurate one nevertheless th...

Page 17: ...ntegrity of the sensor wires their connections and the sensor itself Fault sensor must be replaced Err2 Temperature sensor BT2 readout is beyond the range of 0 300 C during 3 seconds Check integrity of the sensor wires their connections and the sensor itself Fault sensor must be replaced Err3 Sensor BT2 readout exceeds sensor BT1 readout for more than 20 C Check that the sensors are con nected to ...

Page 18: ... to decrease and button 2 to increase the value NOTE all values are represented in dec imal format ds or dd For example 150 ds is equal to 15 seconds Param Meaning Default value A1 Basket return time ds 0150 A2 Basket operation full cycle duration ds 0300 A3 Time to drain stop ds 0030 A4 Drain stop duration ds 0070 P Proportional band dd 0003 I Integral time ds 0500 D Derivative time ds 0100 H1 Te...

Page 19: ...n down in the Quality Con trol check section of the manual that came with this particular unit To exit the setup mode press ON OFF button after all parameters were listed through or just doesn t press anything for 30 seconds The machine will exit automatically 19 ...

Page 20: ...S 5 Electromechanical relays K1 K4 6 Programmable logic controller DC1 7 Temperature regulator DC2 8 Power supply unit PSU 9 Solid state relay VS 10 Circuit breaker QF 11 Buzzer BZ 12 Thermal cut out AT 13 Temperature sensor BT2 14 Temperature sensor BT1 15 Heating element EK 16 Thermal cut out bulb AT 20 ...

Reviews: