END PANEL INSTALLATION
Complete these steps to install the end panel.
1. Position the panel flat on ground with the long edge against the bottom end wall frame member.
2. Locate the D-Rings, which line the top of the end panel, and insert a three-foot piece of black strapping into the center
most D-Ring. Insert 2 additional straps on each side of the center D-Ring if needed. (Space these at every other D-
Ring.)
NOTE:
These straps are used to
temporarily
secure the end panel in place. Add more strapping if needed. To prevent
personal injury or property damage, do not install end panel or main cover during stormy or windy conditions.
3. With the black strapping in place, raise the end panel to the end wall and secure to the end rafter using the D-Rings
and strapping.
NOTE:
Pull the top edge of the end panel to within 6" of the rafter. (Approximately 1 to 2 feet of the end panel material
will remain at and run along the base of the end wall. In a later step, this can be wrapped under the bottom tube of the
end wall frame, or remain as a skirt to direct water away from the shelter.)
The end panel must touch the ground after the top edge of the panel is secured to the rafter.
View is from the inside of the shelter looking at the end panel. Frame and rafter shown are different from your frame.
The technique used to secure the end panel is the same however. Photo shows the main cover already installed.
Strap in D-Ring
Rafter
End Panel
Main Cover
Vertical Frame Tube
for the End Wall
Visit www.ClearSpan.com for additional products and customer assistance.
20 of 40