Appendices
~ Appendix E: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
DID - Device ID
This command selects/reports the device ID.
Command form:
DEVICE
DID
[Value]
Argument details
Name
Description
Device
0–7 or * to select all units
DID
Command form
Value
0–7 (select device ID)
Example:
#77 DID 0
On XAP 400 unit 7 (
#77
), the device ID (
DID
) is set to
0
.
DSPVER - DSP Version
This command reports the version of the DSP code in the unit. the version is a date
and time stamp. This command is read only.
Command form: DEVICE
DSPVER
[value]
Argument details
Name
Description
Device
0–7 or * to select all units
DSPVER
Command form
Value
Null
Example
:
#75 DSPVER
The XAP 400 unit 5 (
#75
) will return the DSP version
(
DSPVER
).
DTMFLVL - DTMF Tone Level
This command selects/reports the DTMF tone’s level.
Command form: DEVICE
DTMFLVL
<Channel> [Value]
Argument details
Name
Description
Units
Device
0–7 or * to select all units
DTMFLVL
Command form
Channel
See Group and Channels, page 103
Value
-12.00 to 12.00
dB
Null to return current state
Example: #72 DTMFLVL 1 6
On XAP 400 unit 2 (#72), the DTMF tone level
(
DTMFLVL
) is set to
6
dB.
Summary of Contents for XAP 400
Page 1: ...Audio Products XAP 400 Audio Conferencing System Installation Operation Manual...
Page 2: ...XAP 400 Audio Conferencing System Installation Operation Manual...
Page 27: ...20 Technical Services Group 1 800 283 5936 USA 1 801 974 3760...
Page 99: ...92 Technical Services Group 1 800 283 5936 USA 1 801 974 3760...
Page 172: ...165 Technical Services Group 1 800 283 5936 USA 1 801 974 3760...
Page 173: ......