BMA CT
88
UPDATING ARRAY FIRMWARE
1. Connect the P-Link cable between the CP2 units and the arrays.
2. Connect the CP2 units with CONVERGE Pro 2 CONSOLE.
3. Open the Firmware Loader screen.
4. Browse for the BMA_CT_vx.x.x.x.mdo file.
5. Download the array firmware.
6. The array(s) will default and reboot after the download of firmware.
7. Units are fully upgraded. (All array units connected via the P-Link on
the site are simultaneously updated.)
TESTING THE ARRAYS
The array must be added to the site using the CONVERGE Pro 2
CONSOLE software. This software also provides the capability of
configuring the beams (enable/disable) and other characteristics
available in Configuration mode. Refer to the online help available with
the CONVERGE Pro 2 CONSOLE software.
V
oLume
& m
ute
These controls are available through the controller configured for your
CONVERGE Pro 2 site.
m
icroPhone
a
rray
Led i
ndicatorS
The illuminated LED indicators on the face of the array change color
when the microphone array is active/muted. You can choose colors to
indicate either state, or even set the indicators to remain off by using
CONVERGE Pro 2 CONSOLE to change Unit Properties for the array.