Wall box Installation
Unpack the wall box from shipping container and make sure to check for small items that may be included. These would be
bagged separately and included in the shipping container.
The wall box is installed via the 2 slots located in the top and bottom of the enclosure. Hold the panel up to the mounting
surface and mark the hole locations with a marker.
Note:
A level may be used to ensure that the panel is mounted straight.
Pilot holes can then be drilled at each mark. Using appropriate fasteners for the material, attach the panel to the surface.
Installing Sealcons
Identify the location of the sealcon – on both size boxes, the sealcon locations have been pre-marked on the inside of
the box for easy identification. There are two sealcon locations for each box.
Use a 1” drill bit (step drill is preferred tool); drill out the plastic area enough so that the water tight strain relief fitting will
fit through the hole
(Figure 1)
.
Install the sealcon through the hole, with the threads on the inside of this box.
If optional strength clamps are used, install them onto the strain relief threads before installing nut to tighten
(Figure 3)
.
Install the nut onto the threads and tighten securely until the fitting will not rotate
(Figure 2)
.
Insert cable through sealcon and tighten dome nut to compress rubber sealing grommet.