Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected] 

12

FieldSmart

®

 Fiber Distribution Point (FDP)

SCD Indoor/Outdoor Wall Box

Installation Manual 

 ______________________________________________________

Manual 019477 REV A - Jan 2018

Standard Warranty

Clearfield warrants to the original purchaser of the Product sold hereunder is free from defects in material and workmanship under normal use and 

service, subject to exceptions stated herein. Product purchased is warranted as follows: Clearfield designed and branded Products are warranted for 

three (3) years: Products manufactured by Clearfield to customer prints and/or specifications are warranted for one (1) year; and any Product Clear

-

field acquires from or through a third-party manufacturer or distributor and resells to Customer as the original customer will carry the manufacturer’s 

pass-through warranty, if any. In all cases, the warranty period commences on the date of shipment to the original purchaser.

Warranty Claim Procedure

If any Product purchased from Clearfield is found defective under the above warranty, the following basic procedure must be followed:

1. 

Customer must contact Clearfield and obtain a Return Materials Authorization

2. 

Following authorization, the Customer ships the product-freight collect-to Clearfield’s manufacturing facility

3. 

Clearfield shall repair or replace the defective Product at its sole option and discretion, and return the repaired or replacement Product to Cus

-

tomer’s site, freight prepaid

Note: If the Product is not found to be defective at Clearfield, the product will be returned to the Customer and the customer billed for freight in both 

directions.

View our warranty policy here: 

https://www.seeclearfield.com/warranty.html

Limitations of Warranty

Correction of defects by repair or replacement, at the option of Clearfield Inc, shall constitute the exclusive sole remedy for a breach of this limited 

warranty. Clearfield shall not be liable under any circumstances for any special, consequential, incidental, punitive, or exemplary damages arising 

out of or in any way connected with the product or with agreement to sell product to buyer, including, but not limited to damages for lost profits, loss 

of use, or for any damages or sums paid by buyer to third parties. The foregoing limitation of liability shall apply whether the claim is based upon 

principles of contract, warranty, negligence or other tort, breach of statutory duty, principles of indemnity or contribution, the failure of any limited or 

exclusive remedy to achieve its essential purpose, or otherwise.

Clearfield will not be responsible for any labor or materials costs associated with installation or incorporation of Clearfield products at customer sites, 

including any costs of alteration, replacement or defective product, or any field repairs.

Other Limitations

Clearfield assumes no warranty liability regarding defects caused by:

1. 

Customer’s modification of Product, excepting installation activities described in Clearfield documentation

2. 

Customer re-packaging of Product for shipment to third parties or destinations other than those originally shipped to by Clearfield, or any de

-

fects suffered during shipping where the Product has been re-packaged

3. 

Customer’s installation or maintenance, excepting activities described in and performed in accordance with Clearfield documentation

4. 

Customer’s improper or negligent use or application of Product

5. 

Other causes external to the Product, including but not limited to accidents, catastrophe, acts of God, government action, war, riot, strikes, civil 

commotion, sovereign conduct, or the acts or conduct of any person or persons not party to or associated with Clearfield

6.  Environmental factors and weathering resulting in aging and damage not necessary or applicable to the function of the product

Summary of Contents for FieldSmart SCD

Page 1: ...FieldSmart Fiber Distribtion Point FDP SCD Indoor Outdoor Wall Box Installation Manual _____________________________________________________ Manual 019477 REV A Jan 2018 ...

Page 2: ...__ Manual 019477 REV A Jan 2018 Table of Contents Application 3 Description 3 Technical Specifications 3 Optional Items 4 Overview for Indoor Outdoor Wall Box 4 Wall box Installation 5 Installing Sealcons 5 Installing U Mount for xPAK in FDP XWB1 6 Installing Universal Cassette Mount for FDP XWB2 7 Installing Cassettes in FDP XWB5 8 Connector Cleaning Procedure 9 Standard Warranty 12 Proprietary N...

Page 3: ...71 cable nut grommet for 24 63 cable Cassette Universal Mounting Kit Box Strain relief fitting nut grommet for 24 63 Ideal for any small count fiber scenario the FieldSmart Small Count Delivery SCD Wall Box accepts up to two Clearview Cassettes providing up to 24 fibers in a discrete footprint or a single Clearview xPAK of 6 fibers in the smaller wall box without sacrificing fiber management The l...

Page 4: ...___________________________________________________ Manual 019477 REV A Jan 2018 Optional Items Optional Accessory Kit P N FDP xAK1 includes 1 Strain relief fitting and nut sealcon 2 Strength member clamps Overview for Indoor Outdoor Wall Box 1 3 4 FDP XWB2 and FDP XWB1 1 Mounting Tabs top and bottom 2 Hinged Side 3 Secondary Security Lock Hole 4 Screws for Additional Security 2 ...

Page 5: ...les can then be drilled at each mark Using appropriate fasteners for the material attach the panel to the surface Installing Sealcons Identify the location of the sealcon on both size boxes the sealcon locations have been pre marked on the inside of the box for easy identification There are two sealcon locations for each box Use a 1 drill bit step drill is preferred tool drill out the plastic area...

Page 6: ...emove contents from plastic bag and carefully cut the different components from the main bracket There is an instruction card included with each U Mount bracket 1 2 Once removed screw the U Mount bracket and retaining clips into the wall box The location for this is located on the back of the instruction card 3 You are now ready to install the xPAK into the wall box See Clearview xPAK install manu...

Page 7: ...rd included with each U Mount bracket P N 012700 1 2 Assemble U Mount Bracket per instruction card Once assembled screw the U Mount bracket and retaining clips into the wall box Location for this is on the back of the instruction card Figure 1 You are now ready to install cassettes into wall box using the thumb screws to fasten the cassettes to the clear brackets Figure 2 See Cassette installation...

Page 8: ... to 4 Clearview Blue Cassettes can be installed and buffer tube slack can be routed around the outside of the radius limiters on the plate The wall box will arrive as shown with the plate installed in the box Twist the threaded rods into the two lower pems on the sides of the plate These rods will be included as a ship along item 1 2 Insert the threaded rods through the holes in the sides of the c...

Page 9: ...lead to scratching of the end face Learn the process of cleaning properly Note It is NOT recommended to use isopropyl alcohol to clean the end face Cleaning an SC LC Connector Cleaning the End Face Place one wiping paper on QbE 2 FiberSafe Cleaning Platen Figure 1 Apply small amount of precision cleaner about 1 in diameter with Electro Wash MX pen on to one end of the wipe Figure 2 Hold end face a...

Page 10: ...rough an Adapter AND the Adapter Itself Lightly moisten the fiber optic swab 2 5mm 38542F or 1 25mm 38040 by spotting a small amount about 1 of Electro Wash PX or Electro Wash MX pen onto the QbE Hold the tip of the swab onto the wetted area and hold for a count of 1 2 3 4 5 Insert the swab into the adapter to the connector press lightly against the connector twist 2 3 times remove and discard Dry...

Page 11: ...end of the wipe Figure 1 Figure 1 Figure 2 Figure 3 Hold end face at a 90 degree angle For APC connection adjust by slightly tilting the container or end face Angle is correct when no drag is felt on the end face Figure 2 Male Connector Lightly moisten one side of the fiber optic swab CC505F by spotting a small amount about 1 of Electro Wash PX or Electro Wash MX pen onto the QbE Hold the swab 1 s...

Page 12: ...lacement at the option of Clearfield Inc shall constitute the exclusive sole remedy for a breach of this limited warranty Clearfield shall not be liable under any circumstances for any special consequential incidental punitive or exemplary damages arising out of or in any way connected with the product or with agreement to sell product to buyer including but not limited to damages for lost profits...

Page 13: ...stall the equipment supplied Every effort has been made to keep the information contained in this document current and accurate as of the date of publication or revision However no guarantee is given or implied that the document is error free or that it is accurate with regard to any specification Technical Support Clearfield Inc can be contacted for any issues that arise with the supplied product...

Reviews: