Slide the sealcon down the length of the cable to the
entrance plate, and secure the sealcon to the plate
by engaging and tightening the locking nut
underneath the entrance plate. If the sealcon dome
nut is not already installed, install after tightening
lock nut, but do
NOT
tighten to secure cable.
Note:
Clearfield recommends the use of a set of
sealcon wrenches (P/N’s 013190 - 40mm, and
013191 - 42mm) to properly tighten the sealcon lock
nut and dome nut. These feature an open channel,
which allows the wrench to slide over cables and
onto the sealcon.
10.
Re-install the entrance plate into the cabinet.
Tighten the 6 bolts until the gasket has been
reduced by half of it’s uncompressed thickness to
ensure a proper seal.