26
FieldSmart
®
Fiber Distribution Hub (FDH)
Installation Manual
_________________________________________________________
Manual 019703 REV B - March 2019
5. Remove the plugs from selected holes in the entrance
plate and feed the cables through. Ensure the
entrance plate gasket is around the cables and below
the entrance plate before proceeding.
Compression Fitting Grommet
Cable Size (Inches)
Small Black Grommet
0.3 - 0.4
Medium Black Grommet
0.41 - 0.5
Gray Grommet (Comes Pre-Installed)
0.51 - 0.79
Large Black Grommet (Comes Pre-Installed)
0.71 - 0.98
6. Select the
compression fitting
grommet size that
most nearly fits the
cable to be installed.
The grommets are
included in the
ship-along hardware.
Note:
If more sealcons or strength member clamps are needed, speak to your sales representative about a cable expansion
kit, part number FMA-XXX-14.