![Clearfield Clearview Blue Installation Manual Download Page 36](http://html1.mh-extra.com/html/clearfield/clearview-blue/clearview-blue_installation-manual_2621165036.webp)
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
36
Clearview Blue Cassette
Installation Manual
_________________________________________________________
Manual 019389 Rev E - July 2018
12 Fiber Singe Ribbon Splice
Route the incoming ribbon in the left
chamber of the splice tray, under the
fiber management tabs.
Bring the incoming ribbon into the
splicing area from the left side.
Trim to length at the ribbon splice
sleeve chip.
Bring the pre-loaded ribbon fiber
pigtail into the splicing area from the
right side
Trim to length at the ribbon splice
sleeve chip.
Trim Here
Splicing in the Cassette: Ribbon
Trim Here
For cassettes using the “left exit” standard entrance or slack storage entances 2L, 1R, or 3R, begin the splicing process as
shown. For “right exit” standard entrance cassettes or ones using slack storage entrances 1L, 3L, or 2R, refer to the Right
Rear Redirect section for special routing instructions.
Note: Standard exit/entrance is determined looking from the back of the cassette.
1.
2.
3.
4.
5.