Clearview Blue Cassette
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
Manual 019389 Rev E - July 2018
Right Rear Redirect
For cassettes utilizing slack storage entrances 1L, 3L and 2R, as well as the “right exit” standard entrance, the incoming
fiber will travel in the same direction as the pre-loaded fiber pigtail. This fiber will need to be redirected in order to allow the
ends of the incoming fiber and the pre-loaded fiber pigtail to meet end-to-end in the splicing area of the splice tray.
Begin by pulling the pre-loaded fiber pigtail
out of the right side of the splice tray.
Following the arrows printed on the splice
tray, route the incoming fiber down into the
right side of the tray, and proceed to loop
up and to the left through the middle of the
splice tray storage area, keeping the fibers
underneath the fiber management tabs.
Turn the fiber downwards and begin to
route inside the left side of the splice tray.