2.5.4. Adjustment of the Azimuth
The azimuth indicates the angle of the stylus relative to the
record, viewed from the front. It should be exactly 90°.
The Azimuth is already preset at factory.
If you need to change the azimuth, please loosen the screw
on the under side of the tonearm near the headshell using
the 1.5 mm allen key (Pic 10). Now you can change the
azimuth. Once the adjustment is finished, lock the screw on
the under side of the arm tube near the headshell.
The installation is done correctly, when at the same time the
armtube is parallel to the marking lines on the gauge, the
diamond tip is on the reference point and the leading edge
of the cartridge is parallel to the lines on the gauge.
Finally lock all screws that had been involved during the
adjustments.
Pic. 12: Azimuth adjustment
Pic. 13: Stylus tip on reference point
2.5.5. Adjustment of the Tracking force
By loosen the screw on the counterweight on the tonearm-tube you ou can adjust the tracking force
of your cartridge by moving the counterweight (shown in the picture below).
red arrow (to the end of the tonearm)
= lesser tracking force
green arrow (to the beginning of the
tonearm)
= more tracking force